Trans 301.20Trans 301.20First aid kit.
Trans 301.20(1)(1)Every HSV shall carry a first aid kit. The container shall be moisture and dust proof. It shall be secured in the vehicle.
Trans 301.20(2)(2)The kit shall be a 10 unit kit or larger containing the following:
- See PDF for table PDF
Trans 301.20(3)(3)All units shall be in a sanitized package.
Trans 301.20 HistoryHistory: Cr. Register, March, 1982, No. 315, eff. 4-1-82.
Trans 301.21Trans 301.21Fuel tank and fuel system integrity.
Trans 301.21(1)(1)In addition to the requirements under 49 CFR 393.65, 393.67 and 393.69, all fuel systems and tanks shall be maintained free of leaks.
Trans 301.21(2)(2)All fuel lines shall be fastened in a manner that will prevent wear.
Trans 301.21 HistoryHistory: Cr. Register, March, 1982, No. 315, eff. 4-1-82; am. (1), Register, April, 1997, No. 496, eff. 5-1-97.
Trans 301.22Trans 301.22Heaters.
Trans 301.22(1)(1)In addition to the requirements under 49 CFR 393.77, a heater shall maintain an inside temperature of not less than 50° fahrenheit throughout the HSV at average minimum January temperatures as established by the U.S. department of commerce, weather bureau, for the area in which the bus is to be operated.
Trans 301.22(2)(2)The heater hose shall be adequately supported to guard against excessive wear or abrasion and may not interfere with or restrict the driver. Heater hose or lines inside the driver or passenger compartment shall be shielded to prevent accidental contact by driver or passengers.
Trans 301.22 HistoryHistory: Cr. Register, March, 1982, No. 315, eff. 4-1-82; am. Register, April, 1997, No. 496, eff. 5-1-97.
Trans 301.23Trans 301.23Instruments and gauges.
Trans 301.23(1)(1)Every HSV originally equipped with any of the following instruments, warning devices, or gauges shall be maintained with that equipment or a comparable replacement in good working condition:
Trans 301.23(1)(a)(a) Air pressure or vacuum, where air or vacuum brakes are used with low energy supply warning system.
Trans 301.23(1)(b)(b) Ammeter, voltmeter or electrical capacity.
Trans 301.23(1)(c)(c) Fuel.
Trans 301.23(1)(d)(d) Oil pressure.
Trans 301.23(1)(e)(e) Water temperature.
Trans 301.23(2)(2)The gauges or instruments shall be mounted in such a manner that each is clearly visible to the seated driver.
Trans 301.23 HistoryHistory: Cr. Register, March, 1982, No. 315, eff. 4-1-82; r. and recr. (1) (intro.), am. (1) (a), Register, April, 1997, No. 496, eff. 5-1-97.
Trans 301.24Trans 301.24Interior.
Trans 301.24(1)(1)The interior of an HSV shall be free of all unnecessary projections likely to cause injury. This standard requires inner lining on ceilings and walls.
Trans 301.24(2)(2)The interior of the HSV shall be kept free of litter or debris.
Trans 301.24 HistoryHistory: Cr. Register, March, 1982, No. 315, eff. 4-1-82; am. (1), r. (2) and (3), renum. (4) to be (2) and am., Register, April, 1997, No. 496, eff. 5-1-97.
Trans 301.25Trans 301.25Lights, lamps, and reflectors.
Trans 301.25(1)(1)The lights, lamps, and reflectors required for an HSV shall conform to the requirements for color, position and type under 49 CFR 393.9 to 393.26, and required by ch. 347, Stats.