DOC 347.10(3)(d)1.1. Youth assigned to a dormitory shall meet the criteria under s. DOC 347.13 (1) (b).
DOC 347.10(3)(d)2.2. Each dormitory shall have a minimum floor area of 35 square feet of unencumbered space per youth for sleeping purposes.
DOC 347.10(3)(d)3.3. In addition, each dormitory shall have a minimum floor area of 35 square feet per youth for the purpose of a dayroom.
DOC 347.10(3)(d)4.4. Each dormitory shall have a floor to ceiling height of not less than 12 feet.
DOC 347.10(3)(d)5.5. Each dayroom shall have tables and seating for the number of youth.
DOC 347.10(3)(d)6.6. A bed shall be provided for each youth.
DOC 347.10(3)(d)7.7. An area for personal property shall be provided for each youth.
DOC 347.10(3)(d)8.8. Each dormitory shall provide showers, toilets, and washbasins for youth. Each dormitory shall have hot and cold running water.
DOC 347.10(3)(e)(e) Toilets, washbasins, and showers.
DOC 347.10(3)(e)1.1. The facility shall provide toilets, washbasins, and showers accessible for youth that meet all of the following conditions:
DOC 347.10(3)(e)1.a.a. The washbasin and toilet may be combined in one unit.
DOC 347.10(3)(e)1.b.b. The washbasin and shower shall have hot and cold running water.
DOC 347.10(3)(e)1.c.c. The washbasin area shall include a mirror that is not removable.
DOC 347.10(3)(e)2.2. The number of showers and toilets provided shall be in compliance with the Wisconsin Commercial Building Code under chs. SPS 361 to 366.
DOC 347.10(3)(e)3.3. Toilets and showers shall provide for individual privacy.
DOC 347.10(3)(f)(f) Lighting. Light fixtures shall provide at least 10 foot-candles of illumination, 30 inches above the floor. The facility shall have the ability to reduce lighting to allow for comfortable sleeping while remaining adequate for wellness checks.
DOC 347.10(4)(4)Receiving rooms.
DOC 347.10(4)(a)(a) All receiving rooms shall be designed and used for single occupancy.
DOC 347.10(4)(b)(b) Each receiving room shall have a floor area of at least 35 square feet of unencumbered space. The distance between the floor and ceiling may not be less than 8 feet, and the distance between opposite walls may not be less than 6 feet.
DOC 347.10(4)(c)(c) Each receiving room shall have all of the following:
DOC 347.10(4)(c)1.1. A bed.
DOC 347.10(4)(c)2.2. A toilet and washbasin with hot and cold running water.
DOC 347.10(4)(c)3.3. Light fixtures that provide at least 10 foot-candles of illumination, 30 inches above the floor. The facility shall have the ability to reduce lighting to allow for comfortable sleeping while remaining adequate for wellness checks.
DOC 347.10(5)(5)Holding rooms.
DOC 347.10(5)(a)(a) A holding room shall have a minimum floor area of at least 50 square feet with an additional 10 square feet for each occupant above 5.
DOC 347.10(5)(b)(b) Each holding room shall have all of the following:
DOC 347.10(5)(b)1.1. Seats or benches.
DOC 347.10(5)(b)2.2. A toilet and washbasin with hot and cold running water.
DOC 347.10(5)(b)3.3. Light fixtures that provide at least 10 foot-candles of illumination, 30 inches above the floor.