DOC 347.10(5)(b)3.3. Light fixtures that provide at least 10 foot-candles of illumination, 30 inches above the floor.
DOC 347.10(6)(6)Multipurpose rooms.
DOC 347.10(6)(a)(a) Each facility shall provide dedicated space for programming and services.
DOC 347.10(6)(b)(b) Multipurpose rooms shall be of sufficient size to accommodate a variety of programming and services and shall have a minimum combined floor area of 300 square feet.
DOC 347.10(7)(7)Classroom space.
DOC 347.10(7)(a)(a) Each facility shall provide dedicated classroom space to meet the educational needs of the youth population.
DOC 347.10(7)(b)(b) Classroom space shall be designed in conformity with any state and local educational requirements.
DOC 347.10(8)(8)Quiet space.
DOC 347.10(8)(a)(a) Each facility shall provide a dedicated quiet space that promotes a positive behavior adjustment opportunity for a youth.
DOC 347.10(8)(b)(b) The quiet space shall not be locked or used for discipline.
DOC 347.10(9)(9)Indoor recreation space.
DOC 347.10(9)(a)(a) Each facility shall provide a dedicated space for indoor exercise and recreation.
DOC 347.10(9)(b)(b) The indoor recreation space shall be of sufficient size to accommodate a variety of individual and group aerobic and large-muscle exercise activities and physical education.
DOC 347.10(10)(10)Outdoor recreation space.
DOC 347.10(10)(a)(a) Each facility shall provide a dedicated space for outdoor exercise and recreation.
DOC 347.10(10)(b)(b) The outdoor recreation space shall be of sufficient size to accommodate a variety of individual and group aerobic and large-muscle exercise activities and physical education.
DOC 347.10(10)(c)(c) The outdoor recreation space must ensure the privacy of the youth and the perimeter shall be secured.
DOC 347.10(11)(11)Healthcare space.
DOC 347.10(11)(a)(a) Each facility shall provide dedicated space for healthcare.
DOC 347.10(11)(b)(b) There shall be sufficient space, equipment, and supplies for the performance of health care services in a confidential manner.
DOC 347.10(12)(12)Food service space. A facility that prepares meals on-site shall have dedicated food service space.
DOC 347.10(13)(13)Receiving space.
DOC 347.10(13)(a)(a) Each facility shall provide dedicated space for youth privacy during searches, showering, and processing.
DOC 347.10(13)(b)(b) There shall be sufficient space for storage of clothing and property.
DOC 347.10(14)(14)Visitation space. Each facility shall provide dedicated contact visitation space.
DOC 347.10(15)(15)Exterior windows. All of the following apply to windows that lead to the exterior of the facility or to an area outside the secure perimeter of the facility:
DOC 347.10(15)(a)(a) Each window shall have security glass of sufficient strength to resist breakage and maintain safety and security to prevent youth from harming themselves and others and to prevent escape.
DOC 347.10(15)(b)(b) Each window shall be mounted in a detention strength frame and designed to prevent escape and the passage of contraband.
DOC 347.10(15)(c)(c) Each window shall prevent persons outside the secure perimeter from entering the facility or observing youth.