Feed for /code/admin_code/sps/safety_and_buildings_and_environment/320_325/320 PDF
Register December 2011 No. 672
Chapter SPS 320
ADMINISTRATION AND ENFORCEMENT
Subchapter I — Purpose and Scope
SPS 320.01 Purpose.
SPS 320.02 Scope.
SPS 320.03 Effective date.
SPS 320.04 Applications.
SPS 320.05 Exemptions.
Subchapter II — Jurisdiction
SPS 320.06 Procedure for municipalities.
SPS 320.065 State jurisdiction.
Subchapter III — Definitions
SPS 320.07 Definitions.
Subchapter IV — Approval and Inspection of One- and 2-Family Dwellings
SPS 320.08 Wisconsin uniform building permit.
SPS 320.085 Notices of intent and termination.
SPS 320.09 Procedure for obtaining uniform building permit.
SPS 320.10 Inspections.
SPS 320.11 Suspension or revocation of Wisconsin uniform building permit.
Subchapter V — Approval and Inspection of Modular Homes and Their Components
SPS 320.12 Scope.
SPS 320.13 Manufacture, sale and installation of homes.
SPS 320.14 Approval procedures.
SPS 320.15 Effect of approval.
SPS 320.16 Suspension and revocation of approval.
SPS 320.17 Effect of suspension and revocation.
Subchapter VI — Approval of Products
SPS 320.18 Building product approvals.
Subchapter VII — Variances, Appeals, Violations and Penalties
SPS 320.19 Petition for variance.
SPS 320.20 Municipal variance from the code.
SPS 320.21 Appeals of orders, determinations, and for extension of time.
SPS 320.22 Penalties and violations.
Subchapter IX — Adoption of Standards
SPS 320.24 Adoption of standards.
Ch. SPS 320 Note Note: Chapter ILHR 20 was renumbered chapter Comm 20 under s. 13.93 (2m) (b) 1., Stats., and corrections made under s. 13.93 (2m) (b) 6. and 7., Stats., Register, January, 1999, No. 517. Chapter Comm 20 was renumbered chapter SPS 320 under s. 13.92 (4) (b) 1., Stats., Register December 2011 No. 672.
subch. I of ch. SPS 320 Subchapter I — Purpose and Scope
SPS 320.01 SPS 320.01 Purpose.
SPS 320.01(1)(1) The purpose of this code is to establish uniform statewide construction standards and inspection procedures for one- and 2-family dwellings and modular homes in accordance with the requirements of ss. 101.60 and 101.70, Stats.
SPS 320.01(2) (2) The purpose of this code is to establish uniform installation and inspection procedures for manufactured homes in accordance with the requirements of s. 101.96, Stats.
SPS 320.01 Note Note: The design and construction of manufactured homes is regulated by the federal Department of Housing and Urban Development under Title 24 CFR Part 3280.
SPS 320.01 Note Note: See ch. SPS 305 for licensing requirements for manufactured home manufacturers and manufactured home installers.
SPS 320.01 Note Note: Other agencies may have regulations that affect the design, construction or placement of the dwelling and accessory structures or systems serving the dwelling. The regulations may necessitate additional administrative procedures or inspections for compliance.
SPS 320.01 History History: Cr. Register, November, 1979, No. 287, eff. 6-1-80; am. Register, March, 1992, No. 435, eff. 4-1-92; CR 06-071: renum. s. Comm 320.01 to be (1) , cr. (2) Register December 2006 No. 612, eff. 4-1-07; correction in (1) made under s. 13.92 (4) (b) 7., Stats., Register March 2009 No. 639.
SPS 320.02 SPS 320.02 Scope.
SPS 320.02(1)(1)General. The provisions of this code apply to all of the following:
SPS 320.02(1)(a) (a) All one- and 2-family dwellings built on or after the effective dates under s. SPS 320.03.
SPS 320.02 Note Note: This includes site-built dwellings, manufactured buildings used as dwellings, modular homes and dwellings that may be designated as cabins, seasonal homes, temporary residences, etc., (except for manufactured or HUD homes, which are covered separately under this section).
SPS 320.02(1)(b) (b) Adult family homes providing care, treatment and services for 3 or 4 unrelated adults built on or after the effective dates under s. SPS 320.03.
SPS 320.02(1)(c) (c) Community-based residential facilities providing care, treatment and services for 5 to 8 unrelated adults built on or after the effective dates under s. SPS 320.03.
SPS 320.02(1)(d) (d) The onsite installation of a mobile home or manufactured home on piers, regardless of the date of production of the home.
SPS 320.02 Note Note: The design and construction of a manufactured home is regulated by the U.S. Department of Housing and Urban Development and is not subject to UDC requirements. Prior to regulation by HUD in 1976, manufactured homes were known as mobile homes and their design and construction were not uniformly regulated. See s. SPS 320.07 (52m) for the statutory definition.
SPS 320.02(1)(e) (e) The onsite installation of a manufactured home, regardless of the type of foundation, where the manufactured home has a production date on or after April 1, 2007.
SPS 320.02(1)(f) (f) The design and construction of a crawlspace, basement or foundation, other than piers, under a manufactured home where the manufactured home has a production date on or after the effective dates under s. SPS 320.03.
SPS 320.02(1)(g) (g) All garages, carports, porches, stoops, decks, balconies, stairways and similar structures that are attached to any building covered under this section that was constructed or had a production date on or after the effective dates under s. SPS 320.03.
SPS 320.02(1)(h) (h) Adjacent, unattached structures listed under par. (g) that serve an exit from a dwelling.
SPS 320.02(2) (2)Municipal ordinances.