NR 257.06 NR 257.06Removal allowances for pretreatment standards. Removal allowances for pretreatment standards pursuant to s. NR 211.13 may be granted for the toxic metals limited by this chapter when the toxic metals are used as indicator pollutants.
NR 257.06 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
subch. I of ch. NR 257 Subchapter I — Rolling With Neat Oils Subcategory
NR 257.10 NR 257.10Applicability; description of the rolling with neat oils subcategory. This subchapter applies to the discharge of pollutants to waters of the state and the introduction of pollutants into POTWs from core and ancillary rolling with neat oils operations.
NR 257.10 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.11 NR 257.11Specialized definitions. In addition to the definitions set forth in s. NR 257.03, the following definitions apply to the terms used in this subchapter:
NR 257.11(1) (1) “Ancillary operation” means any operation which is not a core operation but which is performed on-site following or preceding the rolling operation, such as continuous rod casting, continuous sheet casting, solution heat treatment, and cleaning or etching.
NR 257.11(2) (2) “Core operation” means rolling using neat oils, roll grinding, sawing, annealing, stationary casting, homogenizing, artificial aging, degreasing, and stamping.
NR 257.11 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.12 NR 257.12Effluent limitations representing the degree of effluent reduction attainable by application of the best practicable control technology currently available. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BPT: - See PDF for table PDF
1Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times.
NR 257.12 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.13 NR 257.13Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BAT: - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.13 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.14 NR 257.14New source performance standards. Any new source subject to this subchapter shall achieve the following performance standards: - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1Within the range of 7.0 to 10 at all times.
NR 257.14 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.15 NR 257.15Pretreatment standards for existing sources. Except as provided in ss. NR 211.13 and 211.14, any existing source subject to this subchapter which introduces pollutants into a POTW shall comply with ch. NR 211 and achieve the following pretreatment standards for existing sources: - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.15 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.16 NR 257.16Pretreatment standards for new sources. Except as provided in s. NR 211.13, any new source subject to this subchapter which introduces pollutants into a POTW shall comply with ch. NR 211 and achieve the following pretreatment standards for new sources: - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.16 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
subch. II of ch. NR 257 Subchapter II — The Rolling With Emulsions Subcategory
NR 257.20 NR 257.20Applicability; description of the rolling with emulsions subcategory. This subchapter applies to the discharge of pollutants to waters of the state and the introduction of pollutants into POTWs from core and ancillary rolling with emulsions operations.
NR 257.20 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.21 NR 257.21Specialized definitions. In addition to the definitions set forth in s. NR 257.03, the following definitions apply to the terms used in this subchapter:
NR 257.21(1) (1) “Ancillary operation” means any operation which is not a core operation but which is performed on-site following or preceding the rolling operation, such as direct chill casting, solution heat treatment, cleaning or etching, and degassing.
NR 257.21(2) (2) “Core operation” means rolling using emulsions, roll grinding, stationary casting, homogenizing, artificial aging, annealing, and sawing.
NR 257.21 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.22 NR 257.22Effluent limitations representing the degree of effluent reduction attainable by application of the best practicable control technology currently available. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BPT: - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 The pH shall be maintained within the range of 7.0 to 10.0 at all times, except for those situations when this waste stream is discharged separately and without commingling with any other wastewater, in which case the pH shall be within the range of 6.0 to 10.0 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1Within the range of 7.0 to 10 at all times.
NR 257.22 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.23 NR 257.23Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BAT: - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.23 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.24 NR 257.24New source performance standards. Any new source subject to this subchapter shall achieve the following performance standards: - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 The pH shall be maintained within the range of 7.0 to 10.0 at all times, except for those situations when this waste stream is discharged separately and without commingling with any other wastewater, in which case the pH shall be within the range of 6.0 to 10.0 at all times. - See PDF for table PDF
1Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times.
NR 257.24 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.25 NR 257.25Pretreatment standards for existing sources. Except as provided in ss. NR 211.13 and 211.14, any existing source subject to this subchapter which introduces pollutants into a POTW shall comply with ch. NR 211 and achieve the following pretreatment standards for existing sources - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.25 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.26 NR 257.26Pretreatment standards for new sources. Except as provided in s. NR 211.13, any new source subject to this subchapter which introduces pollutants into a POTW shall comply with ch. NR 211 and achieve the following pretreatment standards for new sources: - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.26 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
subch. III of ch. NR 257 Subchapter III — The Extrusion Subcategory
NR 257.30 NR 257.30Applicability; description of the extrusion subcategory. This subchapter applies to the discharge of pollutants to waters of the state and the introduction of pollutants into POTWs from core and ancillary extrusion operations.
NR 257.30 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.31 NR 257.31Specialized definitions. In addition to the definitions set forth in s. NR 257.03, the following definitions apply to the terms used in this subchapter:
NR 257.31(1) (1) “Ancillary operation” means any operation which is not a core operation but which is performed on-site following or preceding the extrusion operation, such as direct chill casting, press or solution heat treatment, cleaning or etching, degassing, and extrusion press hydraulic fluid leakage.
NR 257.31(2) (2) “Core operation” means extrusion die cleaning, any wet scrubber associated with the die cleaning, dummy block cooling, stationary casting, artificial aging, annealing, degreasing, and sawing.
NR 257.31(3) (3) “Extrusion die cleaning” means an operation in which the steel dies used for aluminum extrusion are cleaned by dipping the dies into a concentrated caustic bath to dissolve the aluminum and then rinsing the dies with water.
NR 257.31 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.32 NR 257.32Effluent limitations representing the degree of effluent reduction attainable by application of the best practicable control technology currently available. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BPT: - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 The pH shall be maintained within the range of 7.0 to 10.0 at all times, except for those situations when this waste stream is discharged separately and without commingling with any other wastewater, in which case the pH shall be within the range of 6.0 to 10.0 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times.
NR 257.32 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.33 NR 257.33Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BAT. Degassing operations may not discharge wastewater pollutants. - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 257.33 History History: Cr. Register, November, 1989, No. 407, eff. 12-1-89.
NR 257.34 NR 257.34New source performance standards. Any new source subject to this subchapter shall achieve the following performance standards. Degassing operations may not discharge wastewater pollutants. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 The pH shall be maintained within the range of 7.0 to 10.0 at all times, except for those situations when this waste stream is discharged separately and without commingling with any other wastewater, in which case the pH shall be within the range of 6.0 to 10.0 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF
1 Within the range of 7.0 to 10 at all times. - See PDF for table PDF