NR 666.103(1)(b) (b) Exemptions. The requirements of this section do not apply to hazardous waste and facilities exempt under ss. NR 666.100 (2) or 666.108.
NR 666.103(1)(c) (c) Prohibition on burning dioxin-listed wastes. The following hazardous waste listed for dioxin and hazardous waste derived from any of these wastes may not be burned in a boiler or industrial furnace operating under an interim license: F020, F021, F022, F023, F026 and F027.
NR 666.103(1)(d) (d) Applicability of ch. NR 665 standards. Owners and operators of boilers and industrial furnaces that burn hazardous waste and are operating under an interim license are subject to all of the following provisions of ch. NR 665, except as provided otherwise by this section:
NR 666.103(1)(d)1. 1. In subch. A of ch. NR 665 (General), s. NR 665.0004.
NR 666.103(1)(d)2. 2. In subch. B of ch. NR 665 (General facility standards), ss. NR 665.0011 to 665.0017.
NR 666.103(1)(d)3. 3. In subch. C of ch. NR 665 (Preparedness and prevention), ss. NR 665.0031 to 665.0037.
NR 666.103(1)(d)4. 4. In subch. D of ch. NR 665 (Contingency plan and emergency procedures), ss. NR 665.0051 to 665.0056.
NR 666.103(1)(d)5. 5. In subch. E of ch. NR 665 (Manifest system, recordkeeping and reporting), ss. NR 665.0071 to 665.0077, except that ss. NR 665.0071, 665.0072 and 665.0076 do not apply to owners and operators of on-site facilities that do not receive any hazardous waste from off-site sources.
NR 666.103(1)(d)6. 6. In subch. G of ch. NR 665 (Closure and long-term care), ss. NR 665.0111 to 665.0115.
NR 666.103(1)(d)7. 7. In subch. H of ch. NR 665 (Financial requirements), ss. NR 665.0141, 665.0142, 665.0143 and 665.0147 to 665.0148, except that states and the federal government are exempt from s. NR 665.0147.
NR 666.103(1)(d)8. 8. Subchapter BB of ch. NR 665 (Air emission standards for equipment leaks), except s. NR 665.1050 (1).
NR 666.103(1)(e) (e) Special requirements for furnaces. The following controls apply during an interim license to industrial furnaces (e.g., kilns, cupolas) that feed hazardous waste for a purpose other than solely as an ingredient (see subd. 2.) at any location other than the hot end where products are normally discharged or where fuels are normally fired:
NR 666.103(1)(e)1. 1. `Controls.'
NR 666.103(1)(e)1.a.a. The hazardous waste shall be fed at a location where combustion gas temperatures are at least 1800 °F.
NR 666.103(1)(e)1.b. b. The owner or operator shall determine that adequate oxygen is present in combustion gases to combust organic constituents in the waste and retain documentation of such determination in the facility record.
NR 666.103(1)(e)1.c. c. For cement kiln systems, the hazardous waste shall be fed into the kiln.
NR 666.103(1)(e)1.d. d. The hydrocarbon controls of s. NR 666.104 (3) or sub. (3) (e) apply upon certification of compliance under sub. (3) irrespective of the CO level achieved during the compliance test.
NR 666.103(1)(e)2. 2. `Burning hazardous waste solely as an ingredient.' A hazardous waste is burned for a purpose other than solely as an ingredient if it meets one of these criteria:
NR 666.103(1)(e)2.a. a. The hazardous waste has a total concentration of nonmetal compounds listed in ch. NR 661 Appendix VIII, exceeding 500 ppm by weight, as-fired, and so is considered to be burned for destruction. The concentration of nonmetal compounds in a waste as-generated may be reduced to the 500 ppm limit by bona fide treatment that removes or destroys nonmetal constituents. Blending for dilution to meet the 500 ppm limit is prohibited and documentation that the waste has not been impermissibly diluted shall be retained in the facility record.
NR 666.103(1)(e)2.b. b. The hazardous waste has a heating value of 5,000 Btu/lb or more, as-fired, and so is considered to be burned as fuel. The heating value of a waste as-generated may be reduced to below the 5,000 Btu/lb limit by bona fide treatment that removes or destroys organic constituents. Blending to augment the heating value to meet the 5,000 Btu/lb limit is prohibited and documentation that the waste has not been impermissibly blended shall be retained in the facility record.
NR 666.103(1)(f) (f) Restrictions on burning hazardous waste that is not a fuel. Prior to certification of compliance under sub. (3), owners and operators may not feed hazardous waste that has a heating value less than 5,000 Btu/lb, as-generated, (except that the heating value of a waste as-generated may be increased to above the 5,000 Btu/lb limit by bona fide treatment; however, blending to augment the heating value to meet the 5,000 Btu/lb limit is prohibited and records shall be kept to document that impermissible blending has not occurred) in a boiler or industrial furnace, except that:
NR 666.103(1)(f)1. 1. Hazardous waste may be burned solely as an ingredient.
NR 666.103(1)(f)2. 2. Hazardous waste may be burned for purposes of compliance testing (or testing prior to compliance testing) for a total period of time not to exceed 720 hours.
NR 666.103(1)(f)3. 3. Such waste may be burned if the department has documentation to show that, prior to August 21, 1991, all of the following conditions were met:
NR 666.103(1)(f)3.a. a. The boiler or industrial furnace was operating under the interim license standards for incinerators provided by subch. O of ch. NR 665, or the interim license standards for thermal treatment units provided by subch. P of ch. NR 665.
NR 666.103(1)(f)3.b. b. The boiler or industrial furnace met the interim license eligibility requirements under s. NR 670.070 for subch. O or subch. P of ch. NR 665.
NR 666.103(1)(f)3.c. c. Hazardous waste with a heating value less than 5,000 Btu/lb was burned prior to that date.
NR 666.103(1)(f)4. 4. Such waste may be burned in a halogen acid furnace if the waste was burned as an excluded ingredient under s. NR 661.0002 (5) prior to February 21, 1991 and documentation is kept on file supporting this claim.
NR 666.103(1)(g) (g) Direct transfer to the burner. If hazardous waste is directly transferred from a transport vehicle to a boiler or industrial furnace without the use of a storage unit, the owner and operator shall comply with s. NR 666.111.
NR 666.103(2) (2) Certification of precompliance.
NR 666.103(2)(a) (a) General. The owner or operator shall provide complete and accurate information specified in par. (b) to the department on or before August 21, 1991, and shall establish limits for the operating parameters specified in par. (c). Such information is termed a “certification of precompliance" and constitutes a certification that the owner or operator has determined that, when the facility is operated within the limits specified in par. (c), the owner or operator believes that, using best engineering judgment, emissions of particulate matter, metals, HCl and Cl2 are not likely to exceed the limits provided by ss. NR 666.105, 666.106 and 666.107. The facility may burn hazardous waste only under the operating conditions that the owner or operator establishes under par. (c) until the owner or operator submits a revised certification of precompliance under par. (h) or a certification of compliance under sub.(3), or until a license is issued.
NR 666.103(2)(b) (b) Information required. All of the following information shall be submitted with the certification of precompliance to support the determination that the limits established for the operating parameters identified in par.(c) are not likely to result in an exceedance of the allowable emission rates for particulate matter, metals, HCl and Cl2:
NR 666.103(2)(b)1. 1. General facility information:
NR 666.103(2)(b)1.a. a. EPA facility ID number.
NR 666.103(2)(b)1.b. b. Facility name, contact person, telephone number and address.
NR 666.103(2)(b)1.c. c. Description of boilers and industrial furnaces burning hazardous waste, including type and capacity of device.
NR 666.103(2)(b)1.d. d. A scaled plot plan showing the entire facility and location of the boilers and industrial furnaces burning hazardous waste.
NR 666.103(2)(b)1.e. e. A description of the air pollution control system on each device burning hazardous waste, including the temperature of the flue gas at the inlet to the particulate matter control system.
NR 666.103(2)(b)2. 2. Except for facilities complying with the Tier I or adjusted Tier I feed rate screening limits for metals or total chlorine and chloride provided by ss. NR 666.106 (2) or (5) and 666.107 (2) (a) or (5), respectively, the estimated uncontrolled (at the inlet to the air pollution control system) emissions of particulate matter, each metal controlled by s. NR 666.106, and hydrogen chloride and chlorine, and all of the following information to support such determinations:
NR 666.103(2)(b)2.a. a. The feed rate (lb/hr) of ash, chlorine, antimony, arsenic, barium, beryllium, cadmium, chromium, lead, mercury, silver and thallium in each feedstream (hazardous waste, other fuels, industrial furnace feedstocks).
NR 666.103(2)(b)2.b. b. The estimated partitioning factor to the combustion gas for the materials identified in subd. 2. a. and the basis for the estimate and an estimate of the partitioning to HCl and Cl2 of total chloride and chlorine in feed materials. To estimate the partitioning factor, the owner or operator shall use either best engineering judgment or the procedures specified in ch. NR 666 Appendix IX.
NR 666.103(2)(b)2.c. c. For industrial furnaces that recycle collected particulate matter (PM) back into the furnace and that will certify compliance with the metals emissions standards under sub. (3) (c) 2. a., the estimated enrichment factor for each metal. To estimate the enrichment factor, the owner or operator shall use either best engineering judgment or the procedures specified in “Alternative Methodology for Implementing Metals Controls" in ch. NR 666 Appendix IX.
NR 666.103(2)(b)2.d. d. If best engineering judgment is used to estimate partitioning factors or enrichment factors under subd. 2. b. or c. respectively, the basis for the judgment. When best engineering judgment is used to develop or evaluate data or information and make determinations under this section, the determinations shall be made by a qualified, registered professional engineer and a certification of the engineer's determinations in accordance with s. NR 670.011 (4) shall be provided in the certification of precompliance.
NR 666.103(2)(b)3. 3. For facilities complying with the Tier I or adjusted Tier I feed rate screening limits for metals or total chlorine and chloride provided by ss. NR 666.106 (2) or (5) and 666.107 (2) (a) or (5), the feed rate (lb/hr) of total chloride and chlorine, antimony, arsenic, barium, beryllium, cadmium, chromium, lead, mercury, silver and thallium in each feed stream (hazardous waste, other fuels, industrial furnace feedstocks).
NR 666.103(2)(b)4. 4. For facilities complying with the Tier II or Tier III emission limits for metals or HCl and Cl2 (under ss. NR 666.106 (3) or (4) or 666.107 (2) (b) or (3)), the estimated controlled (outlet of the air pollution control system) emissions rates of particulate matter, each metal controlled by s. NR 666.106, and HCl and Cl2, and the following information to support such determinations:
NR 666.103(2)(b)4.a. a. The estimated air pollution control system (APCS) removal efficiency for particulate matter, HCl, Cl2, antimony, arsenic, barium, beryllium, cadmium, chromium, lead, mercury, silver and thallium.
NR 666.103(2)(b)4.b. b. To estimate APCS removal efficiency, the owner or operator shall use either best engineering judgment or the procedures prescribed in ch. NR 666 Appendix IX.
NR 666.103(2)(b)4.c. c. If best engineering judgment is used to estimate APCS removal efficiency, the basis for the judgment. Use of best engineering judgment shall be in conformance with provisions of subd. 2. d.
NR 666.103(2)(b)5. 5. Determination of allowable emissions rates for HCl, Cl2, antimony, arsenic, barium, beryllium, cadmium, chromium, lead, mercury, silver and thallium, and the following information to support such determinations:
NR 666.103(2)(b)5.a. a. For all facilities, all of the following:
1) Physical stack height.
2) Good engineering practice stack height as defined by 40 CFR 51.100(ii).
3) Maximum flue gas flow rate.
4) Maximum flue gas temperature.
5) Attach a US geological service topographic map (or equivalent) showing the facility location and surrounding land within 5 km of the facility.
6) Identify terrain type: complex or noncomplex.
7) Identify land use: urban or rural.
NR 666.103(2)(b)5.b. b. For owners and operators using Tier III site specific dispersion modeling to determine allowable levels under s. NR 666.106 (4) or 666.107 (3), or adjusted Tier I feed rate screening limits under s. NR 666.106 (5) or 666.107 (5):
1) Dispersion model and version used.
2) Source of meterological data.
3) The dilution factor in micrograms per cubic meter per gram per second of emissions for the maximum annual average off-site (unless on-site is required) ground level concentration (MEI location).
4) Indicate the MEI location on the map required under subd. 5. a. 5).
NR 666.103(2)(b)6. 6. For facilities complying with the Tier II or III emissions rate controls for metals or HCl and Cl2, a comparison of the estimated controlled emissions rates determined under subd. 4. with the allowable emission rates determined under subd. 5.
NR 666.103(2)(b)7. 7. For facilities complying with the Tier I (or adjusted Tier I) feed rate screening limits for metals or total chloride and chlorine, a comparison of actual feed rates of each metal and total chlorine and chloride determined under subd. 3. to the Tier I allowable feed rates.
NR 666.103(2)(b)8. 8. For industrial furnaces that feed hazardous waste for any purpose other than solely as an ingredient (as defined by sub. (1) (e) 2.) at any location other than the product discharge end of the device, documentation of compliance with sub. (1) (e) 1. a., b. and c.
NR 666.103(2)(b)9. 9. For industrial furnaces that recycle collected particulate matter (PM) back into the furnace and that will certify compliance with the metals emissions standards under sub. (3) (c) 2. a., both of the following:
NR 666.103(2)(b)9.a. a. The applicable particulate matter standard in lb/hr.
NR 666.103(2)(b)9.b. b. The precompliance limit on the concentration of each metal in collected PM.
NR 666.103(2)(c) (c) Limits on operating conditions. The owner and operator shall establish limits on the following parameters consistent with the determinations made under par. (b) and certify (under provisions of par. (i)) to the department that the facility will operate within the limits during interim license when there is hazardous waste in the unit until revised certification of precompliance under par. (h) or certification of compliance under sub. (3):
NR 666.103(2)(c)1. 1. Feed rate of total hazardous waste and (unless complying with the Tier I or adjusted Tier I metals feed rate screening limits under s. NR 666.106 (2) or (5)) pumpable hazardous waste.
NR 666.103(2)(c)2. 2. Feed rate of each metal in all of the following feed streams:
NR 666.103(2)(c)2.a. a. Total feed streams, except that industrial furnaces that comply with the alternative metals implementation approach under par. (d) shall specify limits on the concentration of each metal in collected particulate matter in lieu of feed rate limits for total feedstreams.
NR 666.103(2)(c)2.b. b. Total hazardous waste feed, unless complying with the Tier I or adjusted Tier I metals feed rate screening limits under s. NR 666.106 (2) or (5).
NR 666.103(2)(c)2.c. c. Total pumpable hazardous waste feed, unless complying with the Tier I or adjusted Tier I metals feed rate screening limits under s. NR 666.106 (2) or (5).
NR 666.103(2)(c)3. 3. Total feed rate of chlorine and chloride in total feed streams.
NR 666.103(2)(c)4. 4. Total feed rate of ash in total feed streams, except that the ash feed rate for cement kilns and light-weight aggregate kilns is not limited.
NR 666.103(2)(c)5. 5. Maximum production rate of the device in appropriate units when producing normal product, unless complying with the Tier I or adjusted Tier I feed rate screening limits for chlorine under s. NR 666.107 (2) (a) or (5) and for all metals under s. NR 666.106 (2) or (5), and the uncontrolled particulate emissions do not exceed the standard under s. NR 666.105.
NR 666.103(2)(d) (d) Operating requirements for furnaces that recycle PM. Owners and operators of furnaces that recycle collected particulate matter (PM) back into the furnace and that will certify compliance with the metals emissions controls under sub. (3) (c) 2. a. shall comply with the special operating requirements provided in “Alternative Methodology for Implementing Metals Controls" in ch. NR 666 Appendix IX.
NR 666.103(2)(e) (e) Measurement of feed rates and production rate.
NR 666.103(2)(e)1.1. `General requirements.' Limits on each of the parameters specified in par. (c) (except for limits on metals concentrations in collected particulate matter (PM) for industrial furnaces that recycle collected PM) shall be established and continuously monitored under either of the following methods:
NR 666.103(2)(e)1.a. a. A limit for a parameter may be established and continuously monitored and recorded on an instantaneous basis (i.e., the value that occurs at any time) not to be exceeded at any time.
NR 666.103(2)(e)1.b. b. A limit for a parameter may be established and continuously monitored on an hourly rolling average basis defined as follows:
1) A continuous monitor is one which continuously samples the regulated parameter without interruption, and evaluates the detector response at least once each 15 seconds, and computes and records the average value at least every 60 seconds.
2) An hourly rolling average is the arithmetic mean of the 60 most recent 1-minute average values recorded by the continuous monitoring system.
NR 666.103(2)(e)2. 2. `Rolling average limits for carcinogenic metals and lead.' Feed rate limits for the carcinogenic metals (arsenic, beryllium, cadmium and chromium) and lead may be established either on an hourly rolling average basis as prescribed by subd. 1. b. or on (up to) a 24 hour rolling average basis. If the owner or operator elects to use an averaging period from 2 to 24 hours:
NR 666.103(2)(e)2.a. a. The feed rate of each metal shall be limited at any time to 10 times the feed rate that would be allowed on a hourly rolling average basis.
NR 666.103(2)(e)2.b. b. The continuous monitor shall meet all of the following specifications:
1) A continuous monitor is one which continuously samples the regulated parameter without interruption, and evaluates the detector response at least once each 15 seconds, and computes and records the average value at least every 60 seconds.
2) The rolling average for the selected averaging period is defined as the arithmetic mean of one hour block averages for the averaging period. A one hour block average is the arithmetic mean of the one minute averages recorded during the 60-minute period beginning at one minute after the beginning of preceding clock hour.