NR 247.02(7) (7) Automotive glass laminating. This subcategory covers the processes in which glass is cut, bent, washed, and plastic sheet laminated to produce automobile windshields.
NR 247.02(8) (8) Glass container manufacturing. This subcategory covers the process in which raw materials are melted in a furnace and mechanically processed into glass containers.
NR 247.02(9) (9) Machine pressed and blown glass. (This subcategory is reserved.)
NR 247.02(10) (10) Glass tubing manufacturing. This subcategory covers the process in which raw materials are melted in a furnace and glass tubing is mechanically drawn horizontally from the furnace by the Danner process which requires intermittent cullet quenching.
NR 247.02(11) (11) Television picture tube envelope manufacturing. This subcategory covers the process in which raw materials are melted in a furnace and made into television picture tube envelopes.
NR 247.02(12) (12) Incandescent lamp envelope manufacturing. This subcategory covers the process in which;
NR 247.02(12)(a) (a) Raw materials are melted in a furnace and mechanically processed into incandescent lamp envelopes, or
NR 247.02(12)(b) (b) Such envelopes are made and then etched with hydrofluoric acid to produce frosted envelopes.
NR 247.02(13) (13) Hand pressed and blown glass manufacturing. This subcategory covers the process in which raw materials are melted in a furnace and hand pressed or blown to produce glassware. The subcategory is further subdivided to cover:
NR 247.02(13)(a) (a) The production of leaded glass using hydrofluoric acid finishing techniques,
NR 247.02(13)(b) (b) The production of non-leaded glass using hydrofluoric acid finishing techniques, and
NR 247.02(13)(c) (c) The production of leaded or non-leaded glass without the use of hydrofluoric acid finishing techniques.
NR 247.02 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76.
NR 247.03 NR 247.03Definitions. The following definitions are applicable to terms used in this chapter. Definitions of other terms and meanings of abbreviations are set forth in ch. NR 205.
NR 247.03(1) (1)“Advanced air emission control devices” means air pollution control equipment such as electrostatic precipitators and high energy scrubbers used to treat air discharge after initial treatment such as by knock-out chambers and low energy scrubbers.
NR 247.03(2) (2)“Cullet” means broken or excess glass generated in the process.
NR 247.03(3) (3)“Cullet water” means water which is exclusively and directly applied to molten glass to solidify the glass.
NR 247.03(4) (4)“Furnace pull” means the amount of glass drawn from the glass furnaces.
NR 247.03(5) (5)“Mineral ingredients” means sand, soda ash, limestone, dolomite, cullet and other ingredients.
NR 247.03(6) (6)“NL” means that there are no applicable limitations.
NR 247.03(8) (8)“Product frosted” means that portion of the total furnace pull for the manufacture of incandescent lamp envelopes used in the manufacture of frosted envelopes.
NR 247.03(9) (9)“Tempering” means the process in which glass is heated nearly to the melting point and then rapidly cooled to improve its mechanical and thermal endurance.
NR 247.03 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76; correction in (7) made under s. 13.92 (4) (b) 6., Stats., Register April 2013 No. 688; CR 17-046: r. (7) Register February 2021 No. 782, eff. 6-29-21.
NR 247.04 NR 247.04Compliance with effluent limitations and standards. Discharge of pollutants from facilities subject to the provisions of this chapter may not exceed, as appropriate:
NR 247.04(1) (1)By July 1, 1977 effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available;
NR 247.04(2) (2)By July 1, 1983 effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable;
NR 247.04(3) (3)Pretreatment standards for discharges to publicly owned treatment works;
NR 247.04(4) (4)Standards of performance for new sources.
NR 247.04 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76; r. and recr. Register, August, 1983, No. 332, eff. 9-1-83.
NR 247.06 NR 247.06Application of effluent limitations and standards.
NR 247.06(1)(1)The effluent limitations and standards set forth in this chapter shall be used in accordance with this section to establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this chapter, except as;
NR 247.06(1)(a) (a) They may be modified in accordance with subch. IV of ch. NR 220,
NR 247.06(1)(b) (b) They may be superseded by more stringent limitations and standards necessary to achieve water quality standards or meet other legal requirements, or
NR 247.06(1)(c) (c) They may be supplemented or superseded by standards or prohibitions for toxic pollutants or by additional limitations for other pollutants required to achieve water quality.
NR 247.06(2) (2)The production basis for application of the limitations and standards set forth in this chapter shall be the daily average of a maximum month in each subcategory subject to the provisions of this chapter.
NR 247.06 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76; correction in (1) (a) made under s. 13.92 (4) (b) 7, Stats., Register April 2018 No. 748.
NR 247.10 NR 247.10Effluent limitations, best practicable treatment. The following effluent limitations for all or specific subcategories establish, except as provided in subch. IV of ch. NR 220, the quantity or quality of pollutants or pollutant properties which may be discharged by a facility subject to the provisions of this chapter after application to process wastes of the best practicable control technology currently available.
NR 247.10(1) (1)For subcategories (2) and (3) identified in s. NR 247.02 there shall be no discharge of process wastes to surface waters.
NR 247.10(2) (2)The pH of all discharges shall be within the range of 6.0 to 9.0.
NR 247.10(3) (3)The 30-day average limitations for suspended solids and other parameters are set forth in table 1;
NR 247.10(3)(a) (a) In lbs/ 1000 lbs. or kg/1000 kg. of product for subcategories (1), (4), and (5),
NR 247.10(3)(b) (b) In lbs/1000 sq. ft. for subcategories (6) and (7), which may be converted to g/sq m by multiplying by 4.9 and rounding off to 2 decimal places,
NR 247.10(3)(c) (c) In lbs/1000 lbs. or kg/1000 kg. of furnace pull for subcategories (8), (10), (11) and (12) (a), and of frosted product for subcategory (12) (b), and
NR 247.10(3)(d) (d) In mg/l for subcategory (13).
NR 247.10(4) (4)Daily maximum limitations are;
NR 247.10(4)(a) (a) Twice the 30-day average limitations for subcategories (1), (4), (8), (10), (11), and (12), and
NR 247.10(4)(b) (b) The same as the 30-day average limitations for subcategories (5), (6), and (7) except for the suspended solids limitation for subcategory (6) where it is 1.6 times the 30-day average limitations. - See PDF for table PDF
NR 247.10 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76; correction in (intro.) made under s. 13.92 (4) (b) 7, Stats., Register April 2018 No. 748.
NR 247.11 NR 247.11Effluent limitations, best available treatment. The following effluent limitations for all or specific subcategories establish the quantity or quality of pollutants or pollutant properties which may be discharged by a facility subject to the provisions of this chapter after application to process wastes of the best available technology economically achievable.
NR 247.11(1) (1)For subcategories (1), (2), and (3) identified in s. NR 247.02 there shall be no discharge of process wastes to surface waters.
NR 247.11(2) (2)The pH of all discharges shall be within the range of 6.0 to 9.0.
NR 247.11(3) (3)The 30-day average and daily maximum limitations for suspended solids and other parameters are set forth in table 2;
NR 247.11(3)(a) (a) In lbs/1000 lbs. or kg/1000 kg. of product for subcategories (4) and (5),
NR 247.11(3)(b) (b) In lbs/1000 sq. ft. for subcategories (6) and (7), which may be converted to g/sq m by multiplying by 4.9 and rounding off to 2 decimal places,
NR 247.11(3)(c) (c) In lbs/1000 lbs. or kg/1000 kg. of furnace pull for subcategories (8), (10), (11) and (12) (a), and of frosted product for subcategory (12) (b), and
NR 247.11(3)(d) (d) In mg/l for subcategory (13).
NR 247.11(4) (4)Daily maximum limitations are:
NR 247.11(4)(a) (a) Twice the 30-day average limitations for subcategories (4), (8), (10), (11), and (12), and
NR 247.11(4)(b) (b) The same as the 30-day average limitations for subcategories (5), (6), and (7). - See PDF for table PDF
NR 247.11 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76.
NR 247.12 NR 247.12Standards of performance. The effluent limitations for all or specific subcategories set forth in s. NR 247.11 establish the quantity or quality of pollutants or pollutant properties which may be discharged by a facility which is a new source subject to the provisions of this chapter.
NR 247.12 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76.
NR 247.13 NR 247.13Pretreatment standards. The pretreatment standards for discharges to publicly owned treatment works from sources subject to the provisions of this chapter shall be as set forth in ch. NR 211.
NR 247.13 History History: Cr. Register, June, 1976, No. 246, eff. 7-1-76; r. and recr. Register, August, 1983, No. 332, eff. 9-1-83
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.