NR 440.218(2)(Lm)1. 1. For continuous and intermittent HMIWI, 110% of the lowest 3-hour average charge rate measured during the most recent performance test demonstrating compliance with all applicable emission limits.
NR 440.218(2)(Lm)2. 2. For batch HMIWI, 110% of the lowest daily charge rate measured during the most recent performance test demonstrating compliance with all applicable emission limits.
NR 440.218(2)(m) (m) “Maximum design waste burning capacity" means the following:
NR 440.218(2)(m)1. 1. For intermittent and continuous HMIWI,
C = PV x 15,000/8,500
where:
C is the HMIWI capacity, lb/hr
PV is the primary chamber volume, ft3
15,000 is the primary chamber heat release rate factor, Btu/ft3/hr
8,500 is the standard waste heating value, Btu/lb
NR 440.218(2)(m)2. 2. For batch HMIWI,
C = PV x 4.5/8
where:
C is the HMIWI capacity, lb/hr
PV is the primary chamber volume, ft3
4.5 is the waste density, lb/ft3
8 is the typical hours of operation of a batch HMIWI, hours
NR 440.218(2)(mm) (mm) “Maximum fabric filter inlet temperature" means 110% of the lowest 3-hour average temperature at the inlet to the fabric filter, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with the dioxin/furan emission limit.
NR 440.218(2)(n) (n) “Maximum flue gas temperature" means 110% of the lowest 3-hour average temperature at the outlet from the wet scrubber, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with the mercury emission limit.
NR 440.218(2)(nm) (nm) “Medical/infectious waste" means any waste generated in the diagnosis, treatment or immunization of human beings or animals, in research pertaining thereto, or in the production or testing of biologicals that are listed in subds. 1. to 7. Medical/infectious waste does not include hazardous waste identified or listed under the regulations in 40 CFR part 261; household waste as defined in 40 CFR 261.4 (b) (1); ash from incineration of medical/infectious waste, once the incineration process has been completed; human corpses, remains, and anatomical parts that are intended for internment or cremation; and domestic sewage materials identified in 40 CFR 261.4 (a) (1).
NR 440.218(2)(nm)1. 1. Cultures and stocks of infectious agents and associated biologicals, including cultures from medical and pathological laboratories; cultures and stocks of infectious agents from research and industrial laboratories; wastes from the production of biologicals; discarded live and attenuated vaccines; and culture dishes and devices used to transfer, inoculate and mix cultures.
NR 440.218(2)(nm)2. 2. Human pathological waste, including tissues, organs, and body parts and body fluids that are removed during surgery or autopsy, or other medical procedures, and specimens of body fluids and their containers.
NR 440.218(2)(nm)3. 3. Human blood and blood products including all of the following:
NR 440.218(2)(nm)3.a. a. Liquid waste human blood.
NR 440.218(2)(nm)3.b. b. Products of blood.
NR 440.218(2)(nm)3.c. c. Items saturated or dripping with human blood.
NR 440.218(2)(nm)3.d. d. Items that were saturated or dripping with human blood that are now caked with dried human blood; including serum, plasma, and other blood components, and their containers, which were used or intended for use in either patient care, testing and laboratory analysis or the development of pharmaceuticals. Intravenous bags are also include in this category.
NR 440.218(2)(nm)4. 4. Sharps that have been used in animal or human patient care or treatment or in medical, research or industrial laboratories, including hypodermic needles, syringes with or without the attached needle, pasteur pipettes, scalpel blades, blood vials, needles with attached tubing and culture dishes regardless of presence of infectious agents. Also included are other types of broken or unbroken glassware that were in contact with infectious agents, such as used slides and cover slips.
NR 440.218(2)(nm)5. 5. Animal waste including contaminated animal carcasses, body parts and bedding of animals that were known to have been exposed to infectious agents during research, including research in veterinary hospitals, production of biologicals or testing of pharmaceuticals.
NR 440.218(2)(nm)6. 6. Isolation wastes including biological waste and discarded materials contaminated with blood, excretions, exudates or secretions from humans who are isolated to protect others from certain highly communicable diseases, or isolated animals known to be infected with highly communicable diseases.
NR 440.218(2)(nm)7. 7. Unused sharps including the following unused, discarded sharps: hypodermic needles, suture needles, syringes and scalpel blades.
NR 440.218(2)(o) (o) “Medium HMIWI" means an HMIWI whose maximum design waste burning capacity is more than 200 pounds per hour but less than or equal to 500 pounds per hour, a continuous or intermittent HMIWI whose maximum charge rate is more than 200 pounds per hour but less than or equal to 500 pounds per hour, or a batch HMIWI whose maximum charge rate is more than 1,600 pounds per day but less than or equal to 4,000 pounds per day. A continuous or intermittent HMIWI whose maximum charge rate is less than or equal to 200 pounds per hour or more than 500 pounds per hour or a batch HMIWI whose maximum charge rate is more than 4,000 pounds per day or less than or equal to 1,600 pounds per day is not a medium HMIWI.
NR 440.218(2)(om) (om) “Minimum dioxin/furan sorbent flow rate" means 90% of the highest 3-hour average dioxin/furan sorbent flow rate, taken at a minimum once every hour, measured during the most recent performance test demonstrating compliance with the dioxin/furan emission limit.
NR 440.218(2)(p) (p) “Minimum mercury sorbent flow rate" means 90% of the highest 3-hour average mercury sorbent flow rate, taken at a minimum once every hour, measured during the most recent performance test demonstrating compliance with the mercury emission limit.
NR 440.218(2)(pm) (pm) “Minimum hydrogen chloride sorbent flow rate" means 90% of the highest 3-hour average hydrogen chloride (HCl) sorbent flow rate, taken at a minimum once every hour, measured during the most recent performance test demonstrating compliance with the HCl emission limit.
NR 440.218(2)(q) (q) “Minimum horsepower or amperage" means 90% of the highest 3-hour average horsepower or amperage to the wet scrubber, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with the applicable emission limits.
NR 440.218(2)(qm) (qm) “Minimum pressure drop across the wet scrubber" means 90% of the highest 3-hour average pressure drop across the wet scrubber PM control device, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with the PM emission limit.
NR 440.218(2)(r) (r) “Minimum scrubber liquor flow rate" means 90% of the highest 3-hour average liquor flow rate at the inlet to the wet scrubber, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with all applicable emission limits.
NR 440.218(2)(rm) (rm) “Minimum scrubber liquor pH" means 90% of the highest 3-hour average liquor pH at the inlet to the wet scrubber, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with the HCl emission limit.
NR 440.218(2)(s) (s) “Minimum secondary chamber temperature" means 90% of the highest 3-hour average secondary chamber temperature, taken at a minimum once every minute, measured during the most recent performance test demonstrating compliance with the PM, CO or dioxin/furan emission limits.
NR 440.218(2)(sm) (sm) “Modification" or “modified HMIWI" means any changes to an HMIWI unit after September 15, 1997 if the cumulative costs of the changes, over the life of the unit, exceed 50% of the original cost of the construction and installation of the unit, not including the cost of any land purchased in connection with the construction or installation, updated to current costs; or any physical change in, or change in the method of operation of the unit which increases the amount of any air pollutant emitted by the unit for which standards have been established under section 111 or 129 of the Act (42 USC 7411 or 7429).
NR 440.218(2)(t) (t) “Operating day" means a 24-hour period between 12:00 midnight and the following midnight during which any amount of hospital waste or medical/infectious waste is combusted at any time in the HMIWI.
NR 440.218(2)(tm) (tm) “Operation" means the period during which waste is combusted in the incinerator excluding periods of startup or shutdown.
NR 440.218(2)(u) (u) “Particulate matter" or “PM" means the total particulate matter emitted from an HMIWI as measured by Method 5 or Method 29 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1).
NR 440.218(2)(um) (um) “Pathological waste" means waste material consisting of only human or animal remains, anatomical parts or tissue; the bags or containers used to collect and transport the waste material; and animal bedding if applicable.
NR 440.218(2)(v) (v) “Primary chamber" means the chamber in an HMIWI that receives waste material, in which the waste is ignited, and from which ash is removed.
NR 440.218(2)(vm) (vm) “Pyrolysis" means the endothermic gasification of hospital waste or medical/infectious waste using external energy.
NR 440.218(2)(w) (w) “Secondary chamber" means a component of the HMIWI that receives combustion gases from the primary chamber and in which the combustion process is completed.
NR 440.218(2)(wm) (wm) “Shutdown" means the period of time after all waste has been combusted in the primary chamber. For continuous HMIWI, shutdown shall commence no less than 2 hours after the last charge to the incinerator. For intermittent HMIWI, shutdown shall commence no less than 4 hours after the last charge to the incinerator. For batch HMIWI, shutdown shall commence no less than 5 hours after the high-air phase of combustion has been completed.
NR 440.218(2)(x) (x) “Small HMIWI" means an HMIWI whose maximum design waste burning capacity is less than or equal to 200 pounds per hour, a continuous or intermittent HMIWI whose maximum charge rate is less than or equal to 200 pounds per hour, or a batch HMIWI whose maximum charge rate is less than or equal to 1,600 pounds per day. A continuous or intermittent HMIWI whose maximum charge rate is more than 200 pounds per hour or a batch HMIWI whose maximum charge rate is more than 1,600 pounds per day is not a small HMIWI.
NR 440.218(2)(xm) (xm) “Standard conditions" means a temperature of 205C and a pressure of 101.3 kilopascals.
NR 440.218(2)(y) (y) “Startup" means the period of time between the activation of the system and the first charge to the unit. For batch HMIWI, startup means the period of time between activation of the system and ignition of the waste.
NR 440.218(2)(ym) (ym) “Wet scrubber" means an add-on air pollution control device that utilizes an alkaline scrubbing liquor to collect particulate matter, including nonvaporous metals and condensed organics, or to absorb and neutralize acid gases.
NR 440.218(3) (3)Emission limits.
NR 440.218(3)(a)(a) On and after the date on which the initial performance test is completed or is required to be completed under s. NR 440.08, whichever date comes first, no owner or operator of an affected facility may cause to be discharged into the atmosphere from that affected facility any gases that contain stack emissions in excess of the limits presented in Table 1.
NR 440.218(3)(b) (b) On and after the date on which the initial performance test is completed or is required to be completed under s. NR 440.08, whichever date comes first, no owner or operator of an affected facility may cause to be discharged into the atmosphere from the stack of that affected facility any gases that exhibit greater than 10% opacity, 6-minute block average.
NR 440.218(3)(c) (c) On and after the date on which the initial performance test is completed or is required to be completed under s. NR 440.08, whichever date comes first, no owner or operator of an affected facility utilizing a large HMIWI may cause to be discharged into the atmosphere visible emissions of combustion ash from an ash conveying system, including conveyor transfer points, in excess of 5% of the observation period, that is, 9 minutes per 3-hour period, as determined by Method 22 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1), except as provided in pars. (d) and (e).
NR 440.218(3)(d) (d) The emission limit specified in par. (c) does not cover visible emissions discharged inside buildings or enclosures of ash conveying systems; however, the emission limit does cover visible emissions discharged to the atmosphere from buildings or enclosures of ash conveying systems.
NR 440.218(3)(e) (e) The provisions specified in par. (c) do not apply during maintenance and repair of ash conveying systems. Maintenance or repair or both may not exceed 10 operating days per calendar quarter unless the owner or operator obtains written approval from the department establishing a date whereby all necessary maintenance and repairs of ash conveying systems shall be completed.
NR 440.218(4) (4)Operator training and qualification requirements.
NR 440.218(4)(a)(a) No owner or operator of an affected facility may allow the affected facility to operate at any time unless a fully trained and qualified HMIWI operator is accessible, either at the facility or available within one hour. The trained and qualified HMIWI operator may operate the HMIWI directly or be the direct supervisor of one or more HMIWI operators.
NR 440.218(4)(b) (b) Operator training and qualification shall be obtained through ch. NR 499 or by completing all of the requirements included in pars. (c) to (g).
NR 440.218(4)(c) (c) Training shall be obtained by completing an HMIWI operator training course that includes, at a minimum, all of the following provisions:
NR 440.218(4)(c)1. 1. Twenty four hours of training on the following subjects:
NR 440.218(4)(c)1.a. a. Environmental concerns, including pathogen destruction and types of emissions.
NR 440.218(4)(c)1.b. b. Basic combustion principles, including products of combustion.
NR 440.218(4)(c)1.c. c. Operation of the type of incinerator to be used by the operator, including proper startup, waste charging and shutdown procedures.
NR 440.218(4)(c)1.d. d. Combustion controls and monitoring.
NR 440.218(4)(c)1.e. e. Operation of air pollution control equipment and factors affecting performance, if applicable.
NR 440.218(4)(c)1.f. f. Methods to monitor pollutants (continuous emission monitoring systems and monitoring of HMIWI and air pollution control device operating parameters) and equipment calibration procedures, where applicable.
NR 440.218(4)(c)1.g. g. Inspection and maintenance of the HMIWI, air pollution control devices and continuous emission monitoring systems.
NR 440.218(4)(c)1.h. h. Actions to correct malfunctions or conditions that may lead to malfunction.
NR 440.218(4)(c)1.i. i. Bottom and fly ash characteristics and handling procedures.
NR 440.218(4)(c)1.j. j. Applicable federal, state and local regulations.
NR 440.218(4)(c)1.k. k. Work safety procedures.
NR 440.218(4)(c)1.L. L. Pre-startup inspections.
NR 440.218(4)(c)1.m. m. Recordkeeping requirements.
NR 440.218(4)(c)2. 2. An examination designed and administered by the instructor.
NR 440.218(4)(c)3. 3. Reference material distributed to the attendees covering the course topics.
NR 440.218(4)(d) (d) Qualification shall be obtained by satisfying all of the following:
NR 440.218(4)(d)1. 1. Completion of a training course that satisfies the criteria under par. (c).
NR 440.218(4)(d)2. 2. Either 6 months experience as an HMIWI operator, 6 months experience as a direct supervisor of an HMIWI operator, or completion of at least 2 burn cycles under the observation of 2 qualified HMIWI operators.
NR 440.218(4)(e) (e) Qualification is valid from the date on which the examination is passed or the completion of the required experience, whichever is later.
NR 440.218(4)(f) (f) To maintain qualification, the trained and qualified HMIWI operator shall complete and pass an annual review or refresher course of at least 4 hours covering, at a minimum, all of the following:
NR 440.218(4)(f)1. 1. Update of regulations.
NR 440.218(4)(f)2. 2. Incinerator operation, including startup and shutdown procedures.
NR 440.218(4)(f)3. 3. Inspection and maintenance.
NR 440.218(4)(f)4. 4. Responses to malfunctions or conditions that may lead to malfunction.
NR 440.218(4)(f)5. 5. Discussion of operating problems encountered by attendees.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.