Cahi is the monthly average, as-applied, organic HAP content of coating material, i, expressed as a mass fraction, kg/kg
R is the overall organic HAP control efficiency, percent
MBi is the sum of the mass of coating material, i, as-applied on intermittently-controlled work stations operating in bypass mode and the mass of coating material, i, as-applied on never-controlled work stations, in a month, kg
Mvret is the mass of volatile matter retained in the coated web after curing or drying, or otherwise not emitted to the atmosphere, kg. The value of this term will be zero in all cases except where you choose to take into account the volatile matter retained in the coated web or otherwise not emitted to the atmosphere for the compliance demonstration procedures in this section.
NR 466.25(16)
(16) Always-controlled work stations with more than one capture and control system. If you operate more than one capture system or more than one control device and only have always-controlled work stations, you are in compliance with the emission standards in
s. NR 466.23 (1) (b) 1. for the month if for each web coating line or group of web coating lines controlled by a common control device you satisfy one of the following:
NR 466.25(16)(a)
(a) The volatile matter collection and recovery efficiency as determined by
sub. (9) (a) 1.,
3.,
5. and
6. is at least 95% at an existing affected source and at least 98% at a new affected source.
NR 466.25(16)(b)
(b) The overall organic HAP control efficiency as determined by
sub. (9) (b) 1. to
4. for each web coating line or group of web coating lines served by that control device and a common capture system is at least 95% at an existing affected source and at least 98% at a new affected source.
NR 466.25(16)(c)
(c) The overall organic HAP control efficiency as determined by
sub. (11) (a) 1. to
3. and
(b) 1. for each web coating line or group of web coating lines served by that control device and a common capture system is at least 95% at an existing affected source and at least 98% at a new affected source.
NR 466.25 History
History: CR 07-045: cr. Register April 2008 No. 628, eff. 5-1-08. NR 466.26
NR 466.26 Notifications, reports and records. NR 466.26(1)(1)
What notifications and reports must I submit? NR 466.26(1)(a)(a) Each owner or operator of an affected source subject to this subchapter shall submit the reports specified in
pars. (b) to
(g) to the department.
NR 466.26(1)(b)
(b) You shall submit an initial notification according to the following requirements:
NR 466.26(1)(b)1.
1. Initial notification for existing affected sources shall be submitted no later than one year before the compliance date specified in
s. NR 466.23 (3) (a).
NR 466.26(1)(b)3.
3. For the purpose of this subchapter, a permit application submitted under
ch. NR 407 may be used in lieu of the initial notification required under
s. NR 460.08 (2), provided the same information is contained in the permit application as required by
s. NR 460.08 (2).
NR 466.26(1)(b)4.
4. If you are using a permit application in lieu of an initial notification in accordance with
subd. 3., the permit application shall be submitted by the same due date specified for the initial notification.
NR 466.26(1)(c)
(c) You shall submit a semiannual compliance report according to
subds. 1. and
2.
NR 466.26(1)(c)1.a.
a. The first compliance report shall cover the period beginning on the compliance date that is specified for your affected source in
s. NR 466.23 (3) and ending on June 30 or December 31, whichever date is the first date following the end of the calendar half immediately following the compliance date that is specified for your affected source in
s. NR 466.23 (3).
NR 466.26(1)(c)1.b.
b. The first compliance report shall be postmarked or delivered no later than July 31 or January 31, whichever date follows the end of the calendar half immediately following the compliance date that is specified for your affected source in
s. NR 466.23 (3).
NR 466.26(1)(c)1.c.
c. Each subsequent compliance report shall cover the semiannual reporting period from January 1 to June 30 or the semiannual reporting period from July 1 to December 31.
NR 466.26(1)(c)1.d.
d. Each subsequent compliance report shall be postmarked or delivered no later than July 31 or January 31, whichever date is the first date following the end of the semiannual reporting period.
NR 466.26(1)(c)1.e.
e. For each affected source that is subject to permitting regulations pursuant to
ch. NR 407, and for which the department has established dates for submitting semiannual reports pursuant to
s. NR 407.09 (1) (c) 3. a., you may submit the first and subsequent compliance reports according to the dates the department has established instead of according to the dates in
subd. 1. a. to
d.
NR 466.26(1)(c)2.b.
b. Statement by a responsible official with that official's name, title and signature certifying the accuracy of the content of the report.
NR 466.26(1)(c)2.d.
d. If there are no deviations from any emission limit or operating limit that apply to you, a statement that there were no deviations from any emission limit or operating limit during the reporting period, and that no CMS was inoperative, inactive, malfunctioning, out-of-control, repaired or adjusted.
NR 466.26(1)(c)2.e.
e. For each deviation from an emission limit or operating limit that applies to you and that occurs at an affected source where you are not using a CEMS to comply with the emission limits or operating limits in this subchapter, you shall include the following information:
1) The total operating time of each affected source during the reporting period.
2) Information on the number, duration and cause of deviations, including unknown cause, if applicable, and the corrective action taken.
3) Information on the number, duration and cause for CPMS downtime incidents, if applicable, other than downtime associated with zero and span and other calibration checks.
NR 466.26(1)(c)2.f.
f. For each deviation from an emission limit occurring at an affected source where you are using a CEMS to comply with the emission limit in this subchapter, you shall include the following information:
1) The date and time that each malfunction started and stopped.
2) The date and time that each CEMS and CPMS, if applicable, was inoperative except for zero, low-level and high-level checks.
3) The date and time that each CEMS and CPMS, if applicable, was out-of-control, including the information in
s. NR 460.07 (3) (h).
4) The date and time that each deviation started and stopped and whether each deviation occurred during a period of startup, shutdown or malfunction or during another period.
5) A summary of the total duration, in hours, of each deviation during the reporting period and the total duration of each deviation as a percent of the total source operating time during that reporting period.
6) A breakdown of the total duration of the deviations during the reporting period into those that are due to startup, shutdown, control equipment problems, process problems, other known causes and other unknown causes.
7) A summary of the total duration, in hours, of CEMS and CPMS downtime during the reporting period and the total duration of CEMS and CPMS downtime as a percent of the total source operating time during that reporting period.
8) A breakdown of the total duration of CEMS and CPMS downtime during the reporting period into periods that are due to monitoring equipment malfunctions, non-monitoring equipment malfunctions, quality assurance and quality control calibrations, other known causes and other unknown causes.
9) The date of the latest CEMS and CPMS certification or audit.
10) A description of any changes in CEMS, CPMS or controls since the last reporting period.
NR 466.26(1)(d)
(d) You shall submit a notification of performance tests as specified in
ss. NR 460.06 and
460.08 (5) if you are complying with the emission standard using a control device and you are required to conduct a performance test of the control device. This notification and the site-specific test plan required under
s. NR 460.06 (2) shall identify the operating parameters to be monitored to ensure that the capture efficiency of the capture system and the control efficiency of the control device determined during the performance test are maintained. Unless the department objects to the parameter or requests changes, you may consider the parameter approved.
NR 466.26(1)(f)
(f) You shall submit performance test reports as specified in
s. NR 460.09 (4) (b) if you are using a control device to comply with the emission standard and you have not obtained a waiver from the performance test requirement or you are not exempted from this requirement by
s. NR 466.24 (3) (b). The performance test reports shall be submitted as part of the notification of compliance status required in
par. (e).
NR 466.26(1)(g)
(g) You shall submit startup, shutdown and malfunction reports as specified in
s. NR 460.09 (4) (e), except that the provisions in
ch. NR 460 pertaining to startups, shutdowns and malfunctions do not apply unless a control device is used to comply with this subchapter.
NR 466.26(1)(g)1.
1. If actions taken by an owner or operator during a startup, shutdown or malfunction of an affected source, including actions taken to correct a malfunction, are not consistent with the procedures specified in the affected source's SSMP required by
s. NR 460.05 (4) (c), the owner or operator shall state the information in the report. The startup, shutdown or malfunction report shall consist of a letter containing the name, title and signature of the responsible official who is certifying its accuracy and shall be submitted to the department.
NR 466.26(1)(g)2.
2. Separate startup, shutdown and malfunction reports are not required if the information is included in the report specified in
par. (c) 2. f.
NR 466.26(2)(a)(a) Each owner or operator of an affected source subject to this subchapter shall maintain the records specified in
subds. 1. and
2. on a monthly basis in accordance with the requirements of
s. NR 460.09 (2) (a):
NR 466.26(2)(a)1.e.
e. Overall control efficiency determination using capture efficiency and control device destruction or removal efficiency test results in accordance with the requirements of
s. NR 466.24 (3) (e) and
(f).
NR 466.26(2)(a)1.f.
f. Material use, organic HAP use, volatile matter use and coating solids use and compliance demonstrations using these data in accordance with the requirements of
s. NR 466.25 (2),
(3) and
(4).
NR 466.26(2)(b)
(b) Each owner or operator of an affected source subject to this subchapter shall maintain records of all liquid-liquid material balances performed in accordance with the requirements of
s. NR 466.25. The records shall be maintained in accordance with the requirements of
s. NR 460.09 (2). If you are required to comply with operating limits by
s. NR 466.23 (2), you shall comply with the applicable operating limits in the following table:
-
See PDF for table NR 466.26 History
History: CR 07-045: cr. Register April 2008 No. 628, eff. 5-1-08.