A-382.31 (17) (a) COMBINATION DRAIN AND VENT STACKS.
A-382.31 (17) (c) COMBINATION DRAIN AND VENT LABORATORY SINK VENTING.
A-382.32 (4) (b) INSTALLATION OF TRAPS.
Water closet with integral trap
VERTICAL DISTANCE BETWEEN FIXTURE DRAIN OUTLET AND TRAP
HORIZONTAL DISTANCE BETWEEN FIXTURE DRAIN OUTLET AND TRAP
Pedestal fixtures
(Lavatory, shampoo sink,
drinking fountain or cuspidor)
A-382.33 (6)-2. LOCAL WASTE PIPING.
MAXIMUM LENGTH OF LOCAL WASTE PIPE
A-382.33 (7) AIR-GAPS AND AIR-BREAKS.
A-382.33 (8) (a) WASTE SINKS AND STANDPIPES.
A-382.33 (8) (b) FLOOR SINKS.
A-382.33 (8) (b) FLOOR SINK WITH GRATE OPENING.
A-382.33 (8) (c)–1. LOCAL WASTE PIPING.
A-382.33 (8) (c)-2. LOCAL WASTE PIPING
A-382.33 (8) (d)-1. LOCAL WASTE PIPING SERVING WATER HEATER TEMPERATURE AND PRESSURE RELIEF VALVES.
A-382.33 (8) (d)-2. LOCAL WASTE PIPING SERVING WATER HEATER TEMPERATURE AND PRESSURE RELIEF VALVES
A-382.33 (9) (c) COMMERCIAL GRAVITY DISCHARGE-TYPE CLOTHES WASHERS.
A-382.33 (9) (d)-1. RESIDENTIAL-TYPE CLOTHES WASHERS.
A-382.33 (9) (d)-2. RESIDENTIAL-TYPE DISHWASHERS.
A-382.33 (9) (d)-3. RESIDENTIAL-TYPE DISHWASHERS
KITCHEN SINK WITH OR WITHOUT FOOD WASTE GRINDER
A-382.33 (9) (d)-4. COMMERCIAL DISHWASHERS.
A-382.33 (9) (f)-1. ELEVATOR PIT SUBSOIL AND FLOOR DRAINS. Drains and sumps complying with ss. SPS 382.33 and 382.36 shall be provided. Note: Section SPS 362.3004 (2) (b) includes requirements for the installation of drains and sumps. Section SPS 362.3004 (2) (b) reads: “1. Except as provided in subd. 2., a drain or sump complying with ss. SPS 382.33 and 382.36 shall be provided in an elevator pit. Connection of the drain or sump to a sanitary system is prohibited. 2. An elevator pit is exempt from the sump or drain requirement under subd. 1. for any of the following situations:
a. The floor of an elevator walk-in pit is level with the adjacent floor.
b. The elevator does not extend to the building’s lowest floor level and the pit floor is not in contact with the earth.
c. The pit floor is above adjacent grade where the elevator hoistway shaft has one or more exterior walls.
3. The aggregate capacity for drainage from the pit shall be at least one of the following:
a. 30 gpm in a hoistway with one elevator.
b. 50 gpm in a hoistway with two or three elevators.
c. 80 gpm in a hoistway with four elevators.
Note: Note: See s. SPS 382.36 for the width or diameter and depth of a sump pump located in an elevator pit.” A-382.33 (9) (f)-2. ELEVATOR PIT SUBSOIL AND FLOOR DRAINS.
A-382.33 (9) (g) 1. BAR AND SODA FOUNTAIN SINKS.
ICE COMPARTMENT BAR SINK ICE COMPARTMENT
A-382.33 (9) (g) 2. BEER TAPS, COFFEE MAKERS, GLASS FILLERS AND SODA DISPENSERS.
A-382.33 (9) (g) 3. NOVELTY BOXES AND ICE COMPARTMENTS AND ICE CREAM DIPPER WELLS.
Non-refrigerated ice compartments
A-382.33 (9) (g) 4. REFRIGERATED FOOD STORAGE ROOMS, COMPARTMENTS AND DISPLAY CASES.
Minimum 2 inches between cooler floor drain opening and the rim of receptor
A-382.33 (9) (g) 5. MISCELLANEOUS FOOD HANDLING EQUIPMENT.
A-382.34 (4)-1. GARAGE CATCH BASINS.
Outlet – optional external invert
Open grate cover minimum 24 inch square or diameter
Note: The external-type invert may also be used for inlets.
A-382.34 (4)-2. TRAPPED FIXTURES DISCHARGING TO CATCH BASIN.
A-382.34 (4)-3. TRAPPED FIXTURE DISCHARGING INTO GARAGE CATCH BASIN.
A-382.34 (4)-4. FIXTURES WITHOUT TRAPS DISCHARGING TO CATCH BASIN.
A-382.34 (4)-5. GARAGE CATCH BASIN WITH FIXTURES ON SEPARATE FLOOR LEVELS.
Open grate cover minimum 24 inch square or diameter
Horizontal drain minimum of 2 inches above water level
Minimum 20 times ID from basin to stack serving trapped and vented fixtures
A-382.34 (4)-6. GARAGE CATCH BASIN RECEIVING PRESSURIZED DRAINS.
Open grate cover minimum 24 inch square or diameter
Pressurized drain with maximum velocity 2 feet/second
A-382.34 (5) (b)-1. EXTERIOR GREASE INTERCEPTORS.
GREASE INTERCEPTOR MANHOLE LOCATION
A-382.34 (5) (b)-2. EXTERIOR GREASE INTERCEPTORS.
Terminate at or above finished grade
A-382.34 (5) (c) INTERIOR GREASE INTERCEPTORS.
A–382.34 (6) AUTOMATIC CAR WASHES.
CAR WASH INTERIOR WITH INVERT INSIDE OF BASIN
Capacity value equal to at least 15 times the maximum flow rate
Capacity value equal to at least 5 times the maximum flow rate
CAR WASH INTERIOR WITH INVERT OUTSIDE OF BASIN
Capacity value equal to at least 15 times the maximum flow rate
Capacity value equal to at least 5 times the maximum flow rate