NR 283.015(6) (6) Chemical and thermal reticulation processes for polyurethane foam are not subject to this chapter. Water used in those processes is not considered to be process water as defined in this chapter. However, processes used to further mold or form the reticulated foam are subject to this chapter if they discharge process water.
NR 283.015(7) (7) Processes used to regenerate cellulose and to produce a product from the regenerated cellulose are not subject to this chapter. Processes that mold or form cellulose derivatives are subject to this chapter if they discharge process water.
NR 283.015 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.02 NR 283.02General definitions. In addition to the definitions set forth in ch. NR 205 and s. NR 211.03, the following definitions apply to this chapter:
NR 283.02(1) (1) “Average process water usage flow rate” means the volume of process water used per year by a plastics molding and forming process divided by the number of days per year the process operates, expressed in liters per day. The average process water usage flow rate for a plant with more than one wastewater source in a subcategory is the sum of the average process water usage flow rates for each source in that subcategory.
NR 283.02(2) (2) “Cleaning water” means process water used to clean the surface of an intermediate or final plastic product or to clean the surfaces of equipment used in plastics molding and forming that contact an intermediate or final plastic product. It includes water used in both the detergent wash and rinse cycles of a cleaning process.
NR 283.02(3) (3) “Contact cooling and heating water” means process water that contacts the raw material or plastic product for the purpose of heat transfer during the plastics molding and forming process.
NR 283.02(4) (4) “Crude intermediate plastic material” means plastic material formulated in an on-site polymerization process.
NR 283.02(5) (5) “Existing source” means any point source, except a new source as defined in sub. (9), from which pollutants may be discharged either directly into the waters of the state or into a POTW.
NR 283.02(6) (6) “Finishing water” means process water used to remove waste plastic material generated during a finishing process or to lubricate a plastic product during a finishing process. It includes but is not limited to water used to machine or to assemble intermediate or final plastic products.
NR 283.02(7) (7) “Mass of pollutant that can be discharged” means the pollutant mass calculated by multiplying the pollutant concentration times the average process water usage flow rate.
NR 283.02(8) (8) “NSPS” means new source performance standards.
NR 283.02(9) (9) “New source”, as defined for NSPS and PSNS, means any point source from which pollutants may be discharged either directly into the waters of the state or into a POTW, the construction of which commenced after February 15, 1984.
NR 283.02(10) (10) “PSES” means pretreatment standards for existing sources.
NR 283.02(11) (11) “PSNS” means pretreatment standards for new sources.
NR 283.02(12) (12) “Plastic material” means a synthetic organic polymer, including but not limited to a thermoset polymer, a thermoplastic polymer, or a combination of a natural polymer and a thermoset or thermoplastic polymer, that is solid in its final form and was shaped by flow. The material can be either a homogeneous polymer or a polymer combined with fillers, plasticizers, pigments, stabilizers, or other additives.
NR 283.02(13) (13) “Plastics molding and forming” means a manufacturing process in which plastic materials are blended, molded, formed, or otherwise processed into intermediate or final products.
NR 283.02(14) (14) “Process water” means any raw, service, recycled, or reused water that contacts the plastic product or contacts shaping equipment surfaces, including but not limited to molds and mandrels, that come in contact with the plastic product.
NR 283.02(15) (15) “Volume of process water used per year” means the volume of process water that flows through a plastics molding and forming process over a period of one year.
NR 283.02 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.03 NR 283.03Monitoring and reporting requirements. Compliance with the maximum monthly average effluent limitations and pretreatment standards listed in the tables for each regulated process is required regardless of the number of samples analyzed and averaged. The maximum monthly average effluent limitations and pretreatment standards listed in the tables for each regulated process shall be the basis for monthly average discharge limits in direct discharge permits and for pretreatment standards.
NR 283.03 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
subch. II of ch. NR 283 Subchapter II - Contact Cooling and Heating Water Subcategory
NR 283.10 NR 283.10Applicability; description of the contact cooling and heating water subcategory. This subchapter applies to the discharge of pollutants from processes in the contact cooling and heating water subcategory to waters of the state and the introduction of pollutants into POTWs. The contact cooling and heating water subcategory is limited to processes where process water contacts the raw material or plastic product for the purpose of heat transfer during plastics molding and forming.
NR 283.10 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.11 NR 283.11Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
NR 283.11(1)(1) Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the effluent limitations representing the degree of effluent reduction attainable by the application of BPT, which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a point source times the following pollutant concentrations: - See PDF for table PDF
NR 283.11(2) (2) The department shall obtain the average process water usage flow rate for the contact cooling and heating water processes from the permittee.
NR 283.11 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.12 NR 283.12Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Based on EPA's determination that BPT provides adequate control of toxic pollutants in contact cooling and heating process wastewater, BAT guidelines are equivalent to BPT guidelines.
NR 283.12 Note Note: BAT effluent limitations for bis(2-ethylhexyl) phthalate are reserved.
NR 283.12 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.13 NR 283.13New source performance standards.
NR 283.13(1)(1) Any new source subject to this subchapter shall achieve performance standards which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a new source times the pollutant concentrations indicated in Table 1.
NR 283.13(2) (2) The department shall obtain the average process water usage flow rate for the new source contact cooling and heating water processes from the permittee.
NR 283.13 Note Note: NSPS for bis(2-ethylhexyl) phthalate are reserved.
NR 283.13 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.14 NR 283.14Pretreatment standards for existing sources. Any existing source subject to this subchapter that introduces pollutants into a POTW shall comply with ch. NR 211.
NR 283.14 Note Note: PSES for bis(2-ethylhexyl) phthalate are reserved.
NR 283.14 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.15 NR 283.15Pretreatment standards for new sources. Any new source subject to this subchapter that introduces pollutants into a POTW shall comply with ch. NR 211.
NR 283.15 Note Note: PSNS for bis(2-ethylhexyl) phthalate are reserved.
NR 283.15 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.16 NR 283.16Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
NR 283.16(1)(1) Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the effluent limitations representing the degree of effluent reduction attainable by the application of BCT which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a point source times the pollutant concentrations indicated in Table 1.
NR 283.16(2) (2) The department shall obtain the average process water usage flow rate for the contact cooling and heating water processes from the permittee.
NR 283.16 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
subch. III of ch. NR 283 Subchapter III - Cleaning Water Subcategory
NR 283.20 NR 283.20Applicability; description of the cleaning water subcategory. This subchapter applies to the discharge of pollutants from processes in the cleaning water subcategory to waters of the state and the introduction of pollutants into POTWs. The cleaning water subcategory is limited to processes where process water contacts the surface of an intermediate or final plastic product, or the surfaces of shaping equipment used in plastics molding and forming, for the purpose of surface cleaning.
NR 283.20 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.21 NR 283.21Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
NR 283.21(1)(1) Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the effluent limitations representing the degree of effluent reduction attainable by the application of BPT, which is calculated by multiplying the average process water usage flow rate for the cleaning water processes at a point source times the following pollutant concentrations: - See PDF for table PDF
NR 283.21(2) (2) The department shall obtain the average process water usage flow rate for the cleaning water processes from the permittee.
NR 283.21 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.22 NR 283.22Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Based on EPA's determination that BPT provides adequate control of toxic pollutants in cleaning process wastewater, BAT guidelines are equivalent to BPT guidelines.
NR 283.22 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.23 NR 283.23New source performance standards.
NR 283.23(1)(1) Any new source subject to this subchapter shall achieve performance standards calculated by multiplying the average process water usage flow rate for cleaning processes at a new source times the pollutant concentrations indicated in Table 2.
NR 283.23(2) (2) The department shall obtain the average process water usage flow rate for the new source cleaning water processes from the permittee.
NR 283.23 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.24 NR 283.24Pretreatment standards for existing sources. Any existing source subject to this subchapter that introduces pollutants into a POTW shall comply with ch. NR 211.
NR 283.24 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.25 NR 283.25Pretreatment standards for new sources. Any new source subject to this subchapter that introduces pollutants into a POTW shall comply with ch. NR 211.
NR 283.25 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
subch. IV of ch. NR 283 Subchapter IV - Finishing Water Subcategory
NR 283.30 NR 283.30Applicability; description of the finishing water subcategory. This subchapter applies to the discharge of pollutants from processes in the finishing water subcategory to waters of the state and the introduction of pollutants into POTWs. The finishing water subcategory is limited to processes where process water contacts the plastic product for the purpose of removing waste plastic material or lubricating a plastic product during finishing.
NR 283.30 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.31 NR 283.31Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
NR 283.31(1)(1) Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the effluent limitations representing the degree of effluent reduction attainable by the application of BPT, which is calculated by multiplying the average process water usage flow rate for the finishing water processes at a point source times the following pollutant concentrations: - See PDF for table PDF
NR 283.31(2) (2) The department shall obtain the average process water usage flow rate for the finishing water processes from the permittee.
NR 283.31 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.32 NR 283.32Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Based on EPA's determination that BPT provides adequate control of toxic pollutants in finishing process wastewater, BAT guidelines are equivalent to BPT guidelines.
NR 283.32 Note Note: BAT effluent limitations for bis(2-ethylhexyl) phthalate, di-n-butyl phthalate, and dimethyl phthalate are reserved.
NR 283.32 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.33 NR 283.33New source performance standards.
NR 283.33(1)(1) Any new source subject to this subchapter shall achieve performance standards which are calculated by multiplying the average process water usage flow rate for the finishing water processes at a new source times the pollutant concentrations indicated in Table 3.
NR 283.33(2) (2) The department shall obtain the average process water usage flow rate for the new source finishing water processes from the permittee.
NR 283.33 Note Note: NSPS for bis(2-ethylhexyl) phthalate, di-n-butyl phthalate, and dimethyl phthalate are reserved.
NR 283.33 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.34 NR 283.34Pretreatment standards for existing sources. Any existing source subject to this subchapter that introduces pollutants into a POTW shall comply with ch. NR 211.
NR 283.34 Note Note: PSES for bis(2-ethylhexyl) phthalate, di-n-butyl phthalate, and dimethyl phthalate are reserved.
NR 283.34 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.35 NR 283.35Pretreatment standards for new sources. Any new source subject to this subchapter that introduces pollutants into a POTW shall comply with ch. NR 211.
NR 283.35 Note Note: PSNS for bis(2-ethylhexyl) phthalate, di-n-butyl phthalate, and dimethyl phthalate are reserved.
NR 283.35 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
NR 283.40 NR 283.40Cross-references. The federal citations in this chapter correspond to provisions of the Wisconsin administrative code and Wisconsin statutes. The federal citations may be cross-referenced in the following table: - See PDF for table PDF
NR 283.40 History History: Cr. Register, October, 1987, No. 382, eff. 11-1-87.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.