SPS 332.32
SPS 332.32 Handling materials – general [29 CFR 1910.176]. This is a department rule in addition to the requirements in
29 CFR 1910.176: Conveyor systems passing through more than one room, or from one working level to another, shall be provided in each room, or working level, where exposed to contact, with means to disconnect the power.
SPS 332.32 Note
Note: Storage of incompatible materials is regulated by NFPA 1, as established by the National Fire Protection Association and adopted in chapter SPS 314.
SPS 332.32 History
History: Cr.
Register, February, 1999, No. 518, eff. 3-1-99;
CR 14-060: cons. (intro.) and (1), renum. to (intro.) and am., r. (1) (title) and (2)
Register August 2015 No. 716, eff. 9-1-15.
SPS 332.33
SPS 332.33 General requirements for all machines [29 CFR 1910.212]. These are department rules in addition to the requirements in
29 CFR 1910.212:
SPS 332.33(1)(a)(a) Every machine shall be equipped with a loose pulley, clutch, switch or other adequate means within reaching distance of the normal operating positions of the operator for the purpose of disconnecting the machine from the source of power.
SPS 332.33(1)(b)
(b) Machines on which 2 or more persons work shall be equipped with one or more controls so located that more than one of these persons can quickly disconnect the machine from the source of power.
SPS 332.33(2)(a)(a) Every counterweight, where exposed to contact, shall be enclosed or be equipped with a safety device attached independent of the counterweight support, that shall prevent the weight from falling to a point of less than 7 feet from the floor or working level.
SPS 332.33(2)(b)
(b) Every tension weight exposed to contact shall be enclosed or securely fastened to the tension bar.
SPS 332.33(2)(c)
(c) All springs shall be guarded or otherwise equipped to eliminate any hazard due to breakage of the spring or failure of the mounting.
SPS 332.33(3)
(3) Guarding of hot pipes. All pipes carrying steam or other hot materials within 7 feet of the floor or working platform, that are exposed to contact, shall be covered with an insulating material, or guarded so that contact will not cause personal injury.
SPS 332.33(4)
(4) Prevention of automatic restarting. On applications where injury to the operator might result if motors were to restart after power failures, machines shall be prevented from automatically restarting upon restoration of power.
SPS 332.33(5)
(5) Maintenance. All equipment, machine tools, guards and power-driven machinery shall be operated and maintained in safe condition.
SPS 332.33 Note
Note: For information regarding operation and maintenance of hoists, see ANSI/ASME standard B30.16 - Overhead Hoists (Underhung).
SPS 332.33 History
History: Cr.
Register, February, 1999, No. 518, eff. 3-1-99; cr. (4) and (5),
Register, June, 2000, No. 534, eff. 7-1-00;
CR 14-060: am. (intro.)
Register August 2015 No. 716, eff. 9-1-15.
SPS 332.34
SPS 332.34 Woodworking machinery requirements [29 CFR 1910.213]. These are department rules in addition to the requirements in
29 CFR 1910.213 (h):
SPS 332.34(1)
(1) Limit stop. A stop shall be provided to prevent the forward travel of the blade beyond the front of the table.
SPS 332.34(2)
(2) Return means. Every radial arm saw shall be equipped with a means to return the saw automatically to the back of the table when released at any point of its travel; the means shall prevent the saw from rebounding and may not depend on fiber rope or cord for this function.
SPS 332.34 History
History: Cr.
Register, February, 1999, No. 518, eff. 3-1-99;
CR 14-060: am. (intro.), (2)
Register August 2015 No. 716, eff. 9-1-15.
SPS 332.345
SPS 332.345 Commercial diving operations [29 CFR 1910.401]. Section
29 CFR 1910.401 (a) (2) (ii) is not included as part of this chapter.
SPS 332.345 History
History: CR 01-062: cr.
Register June 2002 No. 558, eff. 7-1-02.
SPS 332.37
SPS 332.37 Motor vehicles [29 CFR 1926.601]. SPS 332.37(1)(1) This is a department exception to the requirements in
29 CFR 1926.601(b)(9): Employees may ride on motor vehicles in other than factory-installed passenger seats equipped with seatbelts only when the speed of the motor vehicle is less than 10 miles per hour.
SPS 332.37(2)
(2) Substitute the following wording for the requirements in
29 CFR 1926.601(b)(10): Dump bodies of all vehicles shall be equipped with a positive means of support that is permanently attached and capable of being locked in position to prevent accidental lowering of the body while maintenance or inspection work is being done or while the vehicle is left unattended.
SPS 332.37 History
History: Cr.
Register, February, 1999, No. 518, eff. 3-1-99;
CR 14-060: cons. (intro.) and (1), renum. to (2) and am., renum. 332.40 (intro.) to 332.37 (1) and am.
Register August 2015 No. 716, eff. 9-1-15.
SPS 332.38
SPS 332.38 Specific excavation requirements [29 CFR 1926.651]. This is a department rule in addition to the requirements in
29 CFR 1926.651: No person may work in an excavation over 4 feet in depth without another person being present at the surface.
SPS 332.38 History
History: Cr.
Register, February, 1999, No. 518, eff. 3-1-99;
CR 04-009: am. (1)
Register August 2004 No. 584, eff. 9-1-04;
CR 14-060: cons. (intro.) and (3), renum. to SPS 332.38 and am., r. (1), (2)
Register August 2015 No. 716, eff. 9-1-15.
SPS 332.50
SPS 332.50 Incorporation of standards by reference. The standards listed in the following table are hereby incorporated by reference into this chapter under the authority provided in s.
101.055 (3) (a), Stats.
SPS 332.50 History
History: Cr.
Register, February, 1999, No. 518, eff. 3-1-99; am. Table 32.50-1, r. and recr. 32.50-2,
Register, June, 2000, No. 534, eff. 7-1-00;
CR 01-062: cr. subd. 11. to 13. in Table 32.50-1
Register June 2002 No. 558, eff. 7-1-02 and cr. subd. 14. in Table 32.50-1
Register June 2002 No. 558, eff. 1-1-03;
CR 04-009: am. (1) and r. and recr. Table 32.50-1
Register August 2004 No. 584, eff. 9-1-04; correction in (1) made under s.
13.92 (4) (b) 7., Stats.,
Register December 2011 No. 672;
CR 14-060: r. (1), (2) (title), 32.50. (2) to SPS 332.50 and am., renum. Table 332.50-1 to Table 332.50 and am., r. Table 332.50-2
Register August 2015 No. 716, eff. 9-1-15.