SPS 363.5401 SPS 363.5401Certificate. The requirements in IECC section R401.3 are not included as part of chs. SPS 361 to 366.
SPS 363.5401 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. 363.5401 from 363.0401 and am., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5402 SPS 363.5402Building envelope requirements.
SPS 363.5402(1)(1)Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5402(2) (2)Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5402(3) (3)Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC sections R402.4, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5402(4) (4)Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5402 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5403 SPS 363.5403Systems.
SPS 363.5403(1)(1)Electrical power and lighting. This is a department rule in addition to the requirements in IECC section R403: In residential buildings having individual dwelling units, provisions shall be made to determine the electrical energy consumed by each tenant by separately metering individual dwelling units.
SPS 363.5403(2) (2)Ducts. Substitute the following wording for the requirements in IECC section R403.3.2: All ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with IMC section 603.9.
SPS 363.5403(3) (3)Protection of piping insulation in residential buildings. The requirements in IECC section R403.4.1 are not included as part of chs. SPS 361 to 366.
SPS 363.5403 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: r. and recr. (2), r. (3) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. 363.5403 from 363.0403 and am., cr. (3), Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5404 SPS 363.5404Lighting equipment. Substitute the following wording for the requirements, but not the exception, in IECC section R404.1: A minimum of 50 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps.
SPS 363.5404 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5405 SPS 363.5405Calculation software tools. This is a department informational note to be used under IECC section R405.6: Note: The federal Department of Energy has developed REScheckTM, a computer program that may be used in demonstrating compliance for a residential building which has no more than 3 stories above grade and has 3 or more dwelling units. The REScheck program may be downloaded at http://www.energycodes.gov. The most recent version of REScheck shall be used to determine code compliance. When using the program, the applicable code must be defined as the “2015 IECC.”
SPS 363.5405 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: renum. from Comm 63.0404 and am. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. 363.5405 from 363.0405 and am., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5502 SPS 363.5502Additions.
SPS 363.5502(1)(1)Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5502(2) (2)Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5502(3) (3)Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC sections R402.4.0, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5502(4) (4)Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5502 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5503 SPS 363.5503Alterations.
SPS 363.5503(1)(1)Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5503(2) (2)Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5503(3) (3)Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC sections R402.4.0, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5503(4) (4)Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5503 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5600 SPS 363.5600Referenced standards. This is a department rule in addition to the requirements in IECC chapter 6[RE]: The following standards are incorporated by reference into chs. SPS 361 to 366:
SPS 363.5600(1) (1) ASTM C177-13, Test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus.
SPS 363.5600(2) (2) ASTM C335/335M-10, Test method for steady state heat transfer properties of horizontal pipe insulation.
SPS 363.5600(3) (3) ASTM C518-15, Test method for steady-state thermal transmission properties by means of the heat flow meter apparatus.
SPS 363.5600(4) (4) ASTM C1363-11, Test method for thermal performance of materials and envelope assemblies by means of a hot box apparatus.
SPS 363.5600 Note Note: ASTM standards may be purchased at www.astm.org or from the American Society for Testing and Materials International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959.
SPS 363.5600 Note Copies of the standards adopted under this section are on file in the offices of the department and the legislative reference bureau.
SPS 363.5600 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18; correction in (intro.) made under s. 13.92 (4) (b) 7., Stats., Register April 2018 No. 748.