NR 679.23(2)
(2) The heater is designed to have a maximum capacity of not more than 0.5 million Btu per hour.
NR 679.23(3)
(3) The combustion gases from the heater are vented to the ambient air.
NR 679.23 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.24
NR 679.24 Off-site shipments. Except as provided in subs.
(1) to
(3), generators shall ensure that their used oil is transported only by transporters who have obtained EPA identification numbers.
NR 679.24(1)
(1)
Self-transportation of small amounts to collection centers. Generators may transport, without an EPA identification number or department solid waste collection and transportation service license, used oil that is generated at the generator's site and used oil collected from household do-it-yourselfers to a used oil collection center if all of the following conditions are met:
NR 679.24(1)(a)
(a) The generator transports the used oil in a vehicle owned by the generator or owned by an employee of the generator.
NR 679.24(1)(b)
(b) The generator transports no more than 55 gallons of used oil at any time.
NR 679.24(2)
(2)
Self-transportation of small amounts to aggregation points owned by the generator. Generators may transport, without an EPA identification number or department solid waste collection and transportation service license, used oil that is generated at the generator's site to an aggregation point if all of the following conditions are met:
NR 679.24(2)(a)
(a) The generator transports the used oil in a vehicle owned by the generator or owned by an employee of the generator.
NR 679.24(2)(b)
(b) The generator transports no more than 55 gallons of used oil at any time.
NR 679.24(2)(c)
(c) The generator transports the used oil to an aggregation point that is owned or operated by the same generator.
NR 679.24(3)
(3)
Tolling arrangements. Used oil generators may arrange for used oil to be transported by a transporter without an EPA identification number if the used oil is reclaimed under a contractual agreement pursuant to which reclaimed oil is returned by the processor or re-refiner to the generator for use as a lubricant, cutting oil or coolant. The contract (known as a "tolling arrangement") shall indicate all of the following:
NR 679.24(3)(b)
(b) That the vehicle used to transport the used oil to the processing or re-refining facility and to deliver recycled used oil back to the generator is owned and operated by the used oil processor or re-refiner.
NR 679.24 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.30
NR 679.30 Do-it-yourselfer used oil collection centers. NR 679.30(1)(1)
Applicability. This section applies to owners or operators of all do-it-yourselfer used oil collection centers, as defined in s.
NR 679.01.
NR 679.30(2)
(2)
Do-it-yourselfer used oil collection center requirements. Owners or operators of all do-it-yourselfer used oil collection centers shall comply with the generator standards in subch.
C.
NR 679.30 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.31
NR 679.31 Used oil collection centers. NR 679.31(1)(1)
Applicability. This section applies to owners or operators of used oil collection centers.
NR 679.31(2)
(2)
Used oil collection center requirements. Owners or operators of all used oil collection centers shall comply with the generator standards in subch.
C.
NR 679.31 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.32
NR 679.32 Used oil aggregation points owned by the generator. NR 679.32(1)(1)
Applicability. This section applies to owners or operators of all used oil aggregation points.
NR 679.32(2)
(2)
Used oil aggregation point requirements. Owners or operators of all used oil aggregation points shall comply with the generator standards in subch.
C.
NR 679.32 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.40(1)(1)
General. This subchapter applies to all used oil transporters, except for any of the following:
NR 679.40(1)(a)
(a) This subchapter does not apply to on-site transportation.
NR 679.40(1)(b)
(b) This subchapter does not apply to generators who transport shipments of used oil totaling 55 gallons or less from the generator to a used oil collection center according to s.
NR 679.24 (1).
NR 679.40(1)(c)
(c) This subchapter does not apply to generators who transport shipments of used oil totaling 55 gallons or less from the generator to a used oil aggregation point owned or operated by the same generator according to s.
NR 679.24 (2).
NR 679.40(1)(d)
(d) This subchapter does not apply to transportation of used oil from household do-it-yourselfers to a regulated used oil generator, collection center, aggregation point, processor or re-refiner or burner subject to this chapter. Except as provided in pars.
(a) to
(c), this subchapter does, however, apply to transportation of collected household do-it-yourselfer used oil from regulated used oil generators, collection centers, aggregation points or other facilities where household do-it-yourselfer used oil is collected.
NR 679.40(2)
(2)
Imports and exports. Transporters who import used oil from abroad or export used oil outside of the United States are subject to this subchapter from the time the used oil enters and until the time it exits Wisconsin.
NR 679.40(3)
(3)
Trucks used to transport hazardous waste. Unless trucks previously used to transport hazardous waste are emptied as described in s.
NR 661.0007 prior to transporting used oil, the used oil is considered to have been mixed with the hazardous waste and shall be managed as hazardous waste unless, under s.
NR 679.10 (2), the hazardous waste and used oil mixture is determined not to be hazardous waste.
NR 679.40(4)
(4)
Other applicable provisions. Used oil transporters who conduct any of the following activities are also subject to the following subchapters:
NR 679.40(4)(a)
(a) Transporters who generate used oil shall also comply with subch.
C.
NR 679.40(4)(b)
(b) Transporters who process or re-refine used oil, except as provided in s.
NR 679.41, shall also comply with subch.
F.
NR 679.40(4)(c)
(c) Transporters who burn off-specification used oil for energy recovery shall also comply with subch.
G.
NR 679.40(4)(d)
(d) Transporters who direct shipments of off-specification used oil from their facility to a used oil burner or first claim that used oil that is to be burned for energy recovery meets the used oil fuel specifications in s.
NR 679.11 shall also comply with subch.
H.
NR 679.40(4)(e)
(e) Transporters who dispose of used oil shall also comply with subch.
I.
NR 679.40 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06;
CR 19-082: am. (3)
Register August 2020 No. 776, eff. 9-1-20.
NR 679.41
NR 679.41 Restrictions on transporters who are not also processors or re-refiners. NR 679.41(1)(1)
Used oil transporters may consolidate or aggregate loads of used oil for purposes of transportation. However, except as provided in subs.
(2) and
(3), used oil transporters may not process used oil unless they also comply with the requirements for processors and re-refiners in subch.
F.
NR 679.41(2)
(2) Transporters may conduct incidental processing operations that occur in the normal course of used oil transportation (e.g., settling and water separation), but that are not designed to produce (or make more amenable for production of) used oil derived products unless they also comply with the processor and re-refiner requirements in subch.
F.
NR 679.41(3)
(3) Transporters of used oil that is removed from oil bearing electrical transformers and turbines and filtered by the transporter or at a transfer facility prior to being returned to its original use are not subject to the processor and re-refiner requirements in subch.
F.
NR 679.41 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.42
NR 679.42 Notification and Licensing. NR 679.42(1)(1)
Identification numbers. Used oil transporters who have not previously complied with the notification requirements of s.
NR 660.07 shall comply with this section and obtain an EPA identification number.
NR 679.42(2)
(2)
Mechanics of notification. A used oil transporter who has not received an EPA identification number may obtain one by notifying the department of its used oil activity by submitting a completed EPA form 8700-12.
NR 679.42 Note
Note: See s.
NR 660.07 for information on obtaining EPA form 8700-12.
NR 679.42(3)
(3)
Licensing. Notwithstanding s.
NR 502.06 (2), used oil transporters shall obtain a department solid waste collection and transportation service license, issued under s.
NR 502.06.
NR 679.42 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.43(1)(1)
Deliveries. A used oil transporter shall deliver all used oil received to any of the following:
NR 679.43(1)(a)
(a) Another used oil transporter, if the transporter has obtained an EPA identification number.
NR 679.43(1)(b)
(b) A used oil processing or re-refining facility who has obtained an EPA identification number.
NR 679.43(1)(c)
(c) An off-specification used oil burner facility who has obtained an EPA identification number.
NR 679.43(2)
(2)
Department of transportation requirements. Used oil transporters shall comply with all applicable requirements under the U.S. department of transportation regulations in
49 CFR parts 171 to
180. Persons transporting used oil that meets the definition of a hazardous material in
49 CFR 171.8 shall comply with all applicable regulations in
49 CFR parts 171 to
180.
NR 679.43(3)(a)(a) In the event of a discharge of used oil during transportation, the transporter shall take appropriate immediate action to protect human health and the environment (e.g., notify appropriate authorities, dike the discharge area).
NR 679.43(3)(b)
(b) If a discharge of used oil occurs during transportation and an official (state or local government or a federal agency) acting within the scope of official responsibilities determines that immediate removal of the used oil is necessary to protect human health or the environment, that official may authorize the removal of the used oil by transporters who do not have EPA identification numbers or department solid waste collection and transportation service licenses.
NR 679.43(3)(c)
(c) An air, rail, highway or water transporter who has discharged used oil shall do all of the following:
NR 679.43(3)(e)
(e) A transporter shall clean up any used oil discharge that occurs during transportation or take action as may be required or approved by federal, state or local officials so that the used oil discharge no longer presents a hazard to human health or the environment.
NR 679.43 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06.
NR 679.44
NR 679.44 Rebuttable presumption for used oil. NR 679.44(1)(1)
To ensure that used oil is not a hazardous waste under the rebuttable presumption of s.
NR 679.10 (2) (a) 2., the used oil transporter shall determine whether the total halogen content of used oil being transported or stored at a transfer facility is above or below 1,000 ppm.
NR 679.44(2)
(2) The transporter shall make this determination by doing either of the following:
NR 679.44(2)(b)
(b) Applying knowledge of the halogen content of the used oil in light of the materials or processes used.
NR 679.44(3)
(3) Used oil containing greater than 1,000 ppm total halogens is presumed to be a hazardous waste because it has been mixed with halogenated hazardous waste listed in subch.
D of ch. NR 661. The owner or operator may rebut this presumption by demonstrating that the used oil does not contain hazardous waste (for example, by showing that the used oil does not contain significant concentrations of halogenated hazardous constituents listed in ch.
NR 661 Appendix VIII).
NR 679.44(3)(a)
(a) The rebuttable presumption does not apply to metalworking oils or fluids containing chlorinated paraffins, if they are processed, through a tolling arrangement as described in s.
NR 679.24 (3), to reclaim metalworking oils or fluids. The presumption does apply to metalworking oils or fluids if the oils or fluids are recycled in any other manner, or are disposed.
NR 679.44(3)(b)
(b) The rebuttable presumption does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the CFCs are destined for reclamation. The rebuttable presumption does apply to used oils contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units.
NR 679.44(4)
(4) Records of analyses conducted or information used to comply with subs.
(1) to
(3) shall be maintained by the transporter for at least 3 years.
NR 679.44 History
History: CR 05-032: cr.
Register July 2006 No. 607, eff. 8-1-06;
CR 16-007: am. (3) (intro.)
Register July 2017 No. 739, eff. 8-1-17.
NR 679.45
NR 679.45 Used oil storage at transfer facilities. Used oil transporters are subject to all applicable spill prevention, control and countermeasures (
40 CFR part 112) in addition to this subchapter. Used oil transporters are also subject to the underground storage tank (ch.
ATCP 93) requirements for used oil stored in underground tanks, whether or not the used oil exhibits any hazardous waste characteristics, in addition to this subchapter.
NR 679.45(1)
(1)
Applicability. This section applies to used oil transfer facilities as defined in s.
NR 679.01. Transfer facilities that store used oil for more than 35 days are regulated under subch.
F.
NR 679.45(2)
(2)
Storage units. Owners or operators of used oil transfer facilities may not store used oil in units other than tanks, containers, or units regulated under ch.
NR 664 or
665.
NR 679.45(3)
(3)
Condition of units. Containers and above ground tanks used to store used oil at transfer facilities shall be all of the following:
NR 679.45(3)(a)
(a) In good condition (no severe rusting, apparent structural defects or deterioration).
NR 679.45(4)
(4)
Secondary containment for containers. Containers used to store used oil at transfer facilities shall be equipped with a secondary containment system.