101.16(3r)(c)2. 2. An irrevocable letter of credit that is issued by a financial institution that is authorized to do business in this state or that is federally chartered. The letter of credit shall be for an initial period of at least one year.
101.16(3r)(c)3. 3. Commercial general liability insurance as an endorsement to an existing policy or as a separate policy from an insurer, or a risk retention group, that is licensed to transact the business of insurance in this state or that is eligible to provide insurance as a surplus lines insurer in one or more states.
101.16(3r)(d) (d) A retail supplier who fails to maintain proof of financial responsibility as required under par. (a) or (b), may not distribute liquefied petroleum gas at retail until such proof is obtained.
101.16(3r)(e) (e) Each retail supplier shall file proof of financial responsibility as required under this subsection with the department.
101.16(3r)(f) (f) A 3rd party that issues a surety bond, a letter of credit, or general liability insurance to a retail supplier for purposes of this subsection shall provide written notice to the retail supplier and to the department at least 60 days before canceling, revoking, suspending, or failing to renew the bond, letter, or insurance.
101.16(3r)(g) (g) A retail supplier that cancels or fails to renew a surety bond, a letter of credit, or general liability insurance shall notify the department at least 60 days before cancelling or failing to renew the bond, letter, or insurance. Upon receipt of the notice, the department shall revoke the retail supplier's license issued under sub. (3g).
101.16(3r)(h) (h) A financial institution that issues an irrevocable letter of credit to a retail supplier for purposes of this subsection shall renew the letter automatically unless notice is given as required under par. (f).
101.16(4) (4)Requirements to provide information.
101.16(4)(a)(a) The person actually performing the work of installing equipment utilizing liquefied petroleum gas for fuel purposes shall furnish the user of the equipment a statement, the form of which shall be prescribed by the department, showing that the design, construction, location, and installation of the equipment conforms with the rules promulgated by the department under this section.
101.16(4)(b)1.1. A person who owns, leases, or uses a propane gas system and who is a customer of a retail supplier shall notify the retail supplier of propane gas for the propane gas system of any interruption in the operation of the propane gas system due to the replacement, modification, repair, or servicing of the propane gas system by any person other than the retail supplier. The customer shall provide the notice at least 7 days in advance of the interruption in the operation of the propane gas system, except as provided in subd. 2. The retail supplier, or the person replacing, modifying, repairing, or servicing the propane gas system, shall perform a check for leaks or other defects in the propane gas system before placing the propane gas system back into operation in the manner required by rule.
101.16(4)(b)2. 2. If the interruption of a propane gas system subject to subd. 1. is due to emergency repair or servicing, the customer shall provide the notice to the retail supplier as soon as possible and no later than 24 hours after the repair or servicing is completed.
101.16(4)(c) (c) Each retail supplier filling a container that is part of a propane gas system shall provide written notice to each customer subject to par. (b) of the customer's duty under par. (b) before the retail supplier's first delivery of propane gas to that customer and shall provide subsequent notices on an annual basis. The notice shall include all of the following information concerning the duty to notify under par. (b):
101.16(4)(c)1. 1. The name, address, and telephone number of the retail supplier.
101.16(4)(c)2. 2. The purpose of giving the notification to the retail supplier.
101.16(4)(c)3. 3. A description of the type of propane gas system that is subject to the notification requirement.
101.16(4)(c)4. 4. A description of the types of activities that constitute a replacement, modification, repair, or servicing of a propane gas system.
101.16(4)(c)5. 5. A copy of the provisions under s. 101.16 (4) (b).
101.16(5) (5)Penalties.
101.16(5)(ac)(ac) Except as provided in par. (am), any person who violates sub. (3) or (4) or any rule promulgated under sub. (2) shall forfeit not less than $10 nor more than $1,000.
101.16(5)(am) (am) Any person who intentionally violates sub. (3) or (4) or any rule promulgated under sub. (2) shall be fined not less than $25 nor more than $2,000, or shall be imprisoned not less than 30 days nor more than 6 months.
101.16(5)(b) (b) Except as provided in par. (c), any retail supplier who violates sub. (3g) or (3r) shall forfeit not less than $500 and not more than $1,000 for the first offense and not less than $2,000 but not more than $5,000 for each subsequent offense.
101.16(5)(c) (c) Any retail supplier who violates sub. (3g) or (3r) shall forfeit not less than $200 and not more than $400 for the first offense and not less than $800 but not more than $2,000 for each subsequent offense if the retail supplier is one of the following:
101.16(5)(c)1. 1. A retail supplier who only fills department of transportation cylinders.
101.16(5)(c)2. 2. A retail supplier who only fills containers for engine and recreational vehicle fueling systems.
101.16(5)(cg) (cg) Paragraphs (b) and (c) do not apply to intentional violations of subs. (3g) or (3r).
101.16(5)(cm) (cm) Except as provided in par. (cn), any retail supplier who intentionally violates sub. (3g) or (3r) shall be imprisoned not less than 30 days nor more than 6 months or shall be fined not less than $500 nor more than $1,000 for the first offense and not less than $2,000 nor more than $5,000 for each subsequent offense.
101.16(5)(cn) (cn) Any retail supplier who only fills department of transportation cylinders or containers for engine and recreational vehicles and who intentionally violates sub. (3g) or (3r) shall be imprisoned not less than 30 days nor more than 6 months or shall be fined not less than $200 nor more than $400 for the first offense and not less than $800 nor more than $2,000 for each subsequent offense.
101.16(5)(cr)1.1. Each day of violation of sub. (3) constitutes a separate offense.
101.16(5)(cr)2. 2. Each day of violation of sub. (3g) constitutes a separate offense.
101.16(5)(cr)3. 3. Each day of violation of sub. (3r) constitutes a separate offense.
101.16(5)(cr)4. 4. Each day of violation of sub. (4) constitutes a separate offense.
101.16(5)(d) (d) If a retail supplier is found in violation of sub. (3g) or (3r), the court shall require that the retail supplier cease distributing liquefied petroleum gas at retail until the retail supplier is issued the license required under sub. (3g).
101.16(5m) (5m)Civil liability.
101.16(5m)(a)(a) Any retail supplier who is licensed under sub. (3g) and who suffers damages caused by the filling of a container that is not a department of transportation cylinder by another retail supplier who is not so licensed may bring an action against the unlicensed retail supplier to do any of the following:
101.16(5m)(a)1. 1. Enjoin the unlicensed retail supplier from distributing liquefied petroleum gas at retail until the retail supplier receives the required license.
101.16(5m)(a)2. 2. Receive monetary damages equal to 3 times the amount of any monetary loss sustained or $2,000, whichever is greater, multiplied by each day that the unlicensed supplier is not licensed under sub. (3g).
101.16(5m)(b) (b) Notwithstanding s. 814.04 (1), a retail supplier who prevails in an action under par. (a) shall be awarded reasonable attorney fees.
101.16(5m)(c) (c) An action under this subsection shall be commenced within 180 days after the cause of action accrues or be barred.
101.16(6) (6)Exemption. This section does not apply to railroads engaged in interstate commerce or to equipment used by them.
101.16 History History: 1971 c. 185 s. 1; Stats. 1971 s. 101.16; 2007 a. 203; 2009 a. 180.
101.16 Cross-reference Cross-reference: See also ss. Comm 5.73 and 40.40, Wis. adm. code.
101.17 101.17 Machines and boilers, safety requirement. No machine, mechanical device, or steam boiler shall be installed or used in this state which does not fully comply with the requirements of the laws of this state enacted for the safety of employees and frequenters in places of employment and public buildings and with the orders of the department adopted and published in conformity with this subchapter. Any person violating this section shall be subject to the forfeitures provided in s. 101.02 (12) and (13).
101.17 History History: 1971 c. 185 ss. 1, 7; 1971 c. 228 ss. 19, 43; Stats. 1971 s. 101.17; 1995 a. 27.
101.17 Cross-reference Cross-reference: See also chs. Comm 18, 33, 34, 41, 43, and 45, Wis. adm. code.
101.175 101.175 Local energy resource systems.
101.175(1) (1) In this section:
101.175(1)(a) (a) "Local energy resource system" means a solar energy system, a wind energy system or a wood energy system.
101.175(1)(b) (b) "Solar energy system" means equipment which directly converts and then transfers or stores solar energy into usable forms of thermal or electrical energy.
101.175(1)(c) (c) "Wind energy system" means equipment which converts and then transfers or stores energy from the wind into usable forms of energy.
101.175(1)(d) (d) "Wood energy system" means woodburning stove or furnace.
101.175(1m) (1m) The purpose of this section is to establish statewide local energy resource system standards to promote accurate consumer evaluation of local energy resource systems and components thereof.
101.175(2) (2) Any manufacturer or retailer prior to the sale in this state of any local energy resource system or components thereof may request the department to issue a seal of quality for each system or component which meets or exceeds the quality standards established by the department under sub. (4).
101.175(3) (3) The department, in consultation with the department of agriculture, trade and consumer protection, shall establish by rule quality standards for local energy resource systems which do not impede development of innovative systems but which do:
101.175(3)(a) (a) Promote accurate consumer evaluation of local energy resource systems and components thereof.
101.175(3)(b) (b) Conform, where feasible, with national performance standards promulgated or recognized by the federal government for local energy resource systems.
101.175(3)(c) (c) Promote the production, marketing and installation of local energy resource systems.
101.175(4) (4) The quality standards under sub. (3) shall include but are not limited to:
101.175(4)(a) (a) The requirement of a warranty and minimum requirements for the contents thereof.
101.175(4)(b) (b) The requirement of an operation and maintenance manual and minimum requirements for the contents thereof.
101.175(4)(c) (c) Minimum specifications for materials, workmanship, durability and efficiency.
101.175(5) (5) Upon request by any manufacturer or retailer of any local energy resource system or components thereof which meet or exceed the quality standards established under sub. (4), the department shall issue an appropriate seal of quality. The department may charge a fee to cover the cost of the seal and to cover the cost of examining the system or its components.
101.175(6) (6) Misrepresentation, misuse or duplication of the department seal of quality issued under sub. (5) shall be deemed deceptive advertising under s. 100.18 (9m).
101.175(7) (7) At the request of any buyer of a local energy resource system the department may inspect any local energy resource system necessary to ascertain compliance with this section.
101.175 History History: 1979 c. 350; 1983 a. 27 s. 2202 (25); 1985 a. 120.
101.175 Cross-reference Cross-reference: See also ch. Comm 71, Wis. adm. code.
101.177 101.177 Refrigeration equipment and ozone-depleting refrigerant.
101.177(1) (1)Definitions. In this section:
101.177(1)(a) (a) "Approved refrigerant reclaiming equipment" means equipment that the department or an independent standards testing organization approved by the department determines will treat ozone-depleting refrigerant removed from refrigeration equipment so that the ozone-depleting refrigerant meets the standard of purity for reclaimed refrigerant established under sub. (4) (a) 1.
101.177(1)(am) (am) "Approved refrigerant recycling equipment" means equipment that the department or an independent standards testing organization approved by the department determines will reduce contaminants in used ozone-depleting refrigerant by oil separation and passes through devices that reduce moisture, acidity and particulate matter.
101.177(1)(b) (b) "Ozone-depleting refrigerant" has the meaning given in s. 100.45 (1) (d).
101.177(1)(c) (c) "Refrigeration equipment" means mechanical vapor compression refrigeration equipment except for a mobile air conditioner, as defined in s. 100.45 (1) (b), or trailer refrigeration equipment, as defined in s. 100.45 (1) (e).
101.177(1)(d) (d) "State agency" means any office, department, agency, institution of higher education, association, society, or other body in state government created or authorized to be created by the constitution or any law, that is entitled to expend moneys appropriated by law, including the legislature and the courts, the Wisconsin Housing and Economic Development Authority, the Bradley Center Sports and Entertainment Corporation, the University of Wisconsin Hospitals and Clinics Authority, the Wisconsin Aerospace Authority, the Wisconsin Quality Home Care Authority, and the Wisconsin Health and Educational Facilities Authority, but excluding the Health Insurance Risk-Sharing Plan Authority and the Lower Fox River Remediation Authority.
101.177(2) (2)Servicing. No person, including a state agency, may install or service a piece of refrigeration equipment that contains ozone-depleting refrigerant unless the person certifies all of the following to the department:
101.177(2)(a) (a) That the person does not use ozone-depleting refrigerant for cleaning purposes, including to clean the interior or exterior surfaces of refrigeration equipment.
101.177(2)(b) (b) That the person transfers the ozone-depleting refrigerant from refrigeration equipment to storage containers using equipment that is approved by the department whenever the person removes ozone-depleting refrigerant from refrigeration equipment.
101.177(2)(c) (c) That the individuals who use the equipment to transfer ozone-depleting refrigerant under par. (b) have the qualifications established under sub. (4) (a) 2.
101.177(2)(d) (d) That the person does not knowingly or negligently release ozone-depleting refrigerant to the environment, except for minimal releases that occur as a result of efforts to recover, reclaim or recycle ozone-depleting refrigerant removed from refrigeration equipment.
101.177(2)(e) (e) That the person inspects and, if necessary, repairs refrigeration equipment that leaks, or is suspected of leaking, before putting additional ozone-depleting refrigerant into that refrigeration equipment.
101.177(2)(g) (g) That, for the purposes of determining whether repairs are necessary under par. (e), the person uses a yearly leak rate identified by the federal environmental protection agency.
101.177(3) (3)Sale of used refrigerant.
101.177(3)(a)(a) After December 31, 1991, no person, including a state agency, may sell used ozone-depleting refrigerant removed from refrigeration equipment for reuse unless the person certifies all of the following to the department:
101.177(3)(a)1. 1. That the person or another person reclaims the ozone-depleting refrigerant using approved refrigerant reclaiming equipment.
101.177(3)(a)2. 2. That the individuals who use the approved refrigerant reclaiming equipment under subd. 1. have the qualifications established under sub. (4) (a) 3.
101.177(3)(b) (b) Paragraph (a) does not apply to a person that sells used ozone-depleting refrigerant removed from refrigeration equipment to another person for reclaiming, as provided in par. (a) 1., by that other person if the person informs the other person that the ozone-depleting refrigerant has not been reclaimed as provided in par. (a) 1.
101.177(3m) (3m)Sale of new or reclaimed refrigerant. No person may sell or offer to sell new or reclaimed ozone-depleting refrigerant except as authorized in s. 100.45 (3) (b) or to one of the following:
101.177(3m)(a) (a) A person who intends to resell the ozone-depleting refrigerant.
101.177(3m)(b) (b) A person who provides certification to the department under sub. (2).
Loading...
Loading...
This is an archival version of the Wis. Stats. database for 2009. See Are the Statutes on this Website Official?