(Equation 1)
where:
HC is the mass of organic HAP emission reduction for the controlled coating operation during the month, kg (lb)
AC is the total mass of organic HAP in the coatings used in the controlled coating operation during the month, kg (lb), as calculated in Equation 1A of this subsection
BC is the total mass of organic HAP in the thinners and other additives used in the controlled coating operation during the month, kg (lb), as calculated in Equation 1B of this subsection
CC is the total mass of organic HAP in the cleaning materials used in the controlled coating operation during the month, kg (lb), as calculated in Equation 1C of this subsection
RW is the total mass of organic HAP in waste materials sent or designated for shipment to a hazardous waste TSDF for treatment or disposal during the compliance period, kg (lb), determined according to s. NR 465.47 (2) (e) 2. You may assign a value of zero to RW if you do not wish to use this allowance.
HUNC is the total mass of organic HAP in the coatings, thinners and other additives, and cleaning materials used during all deviations specified in sub. (4) (c) and (d) that occurred during the month in the controlled coating operation, kg (lb), as calculated in Equation 1D of this subsection
CE is the capture efficiency of the emission capture system vented to the add-on control device, percent. Use the test methods and procedures specified in subs. (5) and (6) to measure and record capture efficiency.
DRE is the organic HAP destruction or removal efficiency of the add-on control device, percent. Use the test methods and procedures in subs. (5) and (7) to measure and record the organic HAP destruction or removal efficiency.
(Equation 1A)
where:
AC is the total mass of organic HAP in the coatings used in the controlled coating operation during the month, kg (lb)
Volc,i is the total volume of coating i used during the month, liters (gallons)
Dc,i is the density of coating i, kg per liter (lb per gallon)
Wc,i is the mass fraction of organic HAP in coating i, kg per kg (lb per lb). For reactive adhesives, use the mass fraction of organic HAP that is emitted as determined using the method in to 40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in s. NR 484.04 (24r).
m is the number of different coatings used
(Equation 1B)
where:
BC is the total mass of organic HAP in the thinners and other additives used in the controlled coating operation during the month, kg (lb)
Volt,j is the total volume of thinner or other additive j used during the month, liters (gallons)
Dt,j is the density of thinner or other additive j, kg per liter (lb per gallon)
Wt,j is the mass fraction of organic HAP in thinner or other additive, j, kg per kg (lb per lb). For reactive adhesives, use the mass fraction of organic HAP that is emitted as determined using the method in 40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in s. NR 484.04 (24r).
n is the number of different thinners and other additives used
(Equation 1C)
where:
CC is the total mass of organic HAP in the cleaning materials used in the controlled coating operation during the month, kg (lb)
Vols,k = Total volume of cleaning material, k, used during the month, liters (gallons)
Ds,k is the density of cleaning material, k, kg per liter (lb per gallon)
Ws,k is the mass fraction of organic HAP in cleaning material, k, kg per kg (lb per lb)
p is the number of different cleaning materials used
(Equation 1D)
where:
HUNC is the total mass of organic HAP in the coatings, thinners and other additives, and cleaning materials used during all deviations specified in sub. (4)(c) and (d) that occurred during the month in the controlled coating operation, kg (lb)
Volh is the total volume of coating, thinner or other additive, or cleaning material, h, used in the controlled coating operation during deviations, liters (gallons)
Dh is the density of coating, thinner or other additive, or cleaning material, h, kg per liter (lb per gallon)
Wh is the mass fraction of organic HAP in coating, thinner, other additive or cleaning material, h, kg (lb) of organic HAP per kg (lb) of coating. For reactive adhesives , use the mass fraction of organic HAP that is emitted as determined using the method in 40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in s. NR 484.04 (24r).
q is the number of different coatings, thinners and other additives, and cleaning materials used
NR 465.48(2)(j) (j) Calculate the organic HAP emission reduction for each controlled coating operation using liquid-liquid material balances. For each controlled coating operation using a solvent recovery system for which you conduct liquid-liquid material balances, calculate the organic HAP emission reduction by applying the volatile organic matter collection and recovery efficiency to the mass of organic HAP contained in the coatings, thinners and other additives, and cleaning materials that are used in the coating operation or operations controlled by the solvent recovery system during each month. Perform a liquid-liquid material balance for each month as specified in subds. 1. to 6. Calculate the mass of organic HAP emission reduction by the solvent recovery system as specified in subd. 7.
NR 465.48(2)(j)1. 1. For each solvent recovery system, install, calibrate, maintain and operate according to the manufacturer's specifications, a device that indicates the cumulative amount of volatile organic matter recovered by the solvent recovery system each month. The device shall be initially certified by the manufacturer to be accurate to within plus or minus 2.0% of the mass of volatile organic matter recovered.
NR 465.48(2)(j)2. 2. For each solvent recovery system, determine the mass of volatile organic matter recovered for the month, based on measurement with the device required in subd. 1.
NR 465.48(2)(j)3. 3. Determine the mass fraction of volatile organic matter for each coating, thinner, other additive and cleaning material used in the coating operation or operations controlled by the solvent recovery system during the month, kg (lb) of volatile organic matter per kg (lb) of coating. You may determine the volatile organic matter mass fraction using Method 24 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), or an EPA approved alternative method, or you may use information provided by the manufacturer or supplier of the coating. In the event of any inconsistency between information provided by the manufacturer or supplier and the results of Method 24 or an approved alternative method, the test method results will take precedence unless, after consultation, you demonstrate to the satisfaction of the department that the formulation data are correct.
NR 465.48(2)(j)4. 4. Determine the density of each coating, thinner, other additive and cleaning material used in the coating operation or operations controlled by the solvent recovery system during the month, kg per liter (lb per gallon), according to s. NR 465.47 (2) (c).
NR 465.48(2)(j)5. 5. Measure the volume of each coating, thinner, other additive and cleaning material used in the coating operation or operations controlled by the solvent recovery system during the month, liters (gallons).
NR 465.48(2)(j)6. 6. Each month, calculate the solvent recovery system's volatile organic matter collection and recovery efficiency, using the following equation:
(Equation 2)
where:
RV is the volatile organic matter collection and recovery efficiency of the solvent recovery system during the month, percent
MVR is the mass of volatile organic matter recovered by the solvent recovery system during the month, kg (lb)
Voli is the volume of coating, i, used in the coating operation controlled by the solvent recovery system during the month, liters (gallons)
Di is the density of coating, i, kg per liter (lb per gallon)
WVc,i is the mass fraction of volatile organic matter for coating i, kg (lb) of volatile organic matter per kg (lb) of coating. For reactive adhesives, use the mass fraction of organic HAP that is emitted as determined using the method in 40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in s. NR 484.04 (24r).
Volj is the volume of thinner or other additive, j, used in the coating operation controlled by the solvent recovery system during the month, liters (gallons)
Dj is the density of thinner or other additive, j, kg per liter (lb per gallon)
WVt,j is the mass fraction of volatile organic matter for thinner or other additive, j, kg (lb) of volatile organic matter per kg (lb) of thinner or other additive. For reactive adhesives, use the mass fraction of organic HAP that is emitted as determined using the method in 40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in s. NR 484.04 (24r).
Volk is the volume of cleaning material, k, used in the coating operation controlled by the solvent recovery system during the month, liters (gallons)
Dk is the density of cleaning material, k, kg per liter (lb per gallon)
WVs,k is the mass fraction of volatile organic matter for cleaning material, k, kg (lb) of volatile organic matter per kg (lb) of cleaning material
m is the number of different coatings used in the coating operation controlled by the solvent recovery system during the month
n is the number of different thinners and other additives used in the coating operation controlled by the solvent recovery system during the month
p is the number of different cleaning materials used in the coating operation controlled by the solvent recovery system during the month
NR 465.48(2)(j)7. 7. Calculate the mass of organic HAP emission reduction for the coating operations controlled by the solvent recovery system during the month, using the following equations:
(Equation 3)
where:
HCSR is the mass of organic HAP emission reduction for the coating operation or operations controlled by the solvent recovery system using a liquid-liquid material balance during the month, kg (lb)
ACSR is the total mass of organic HAP in the coatings used in the coating operation or operations controlled by the solvent recovery system, kg (lb), calculated using Equation 3A of this subsection
BCSR is the total mass of organic HAP in the thinners and other additives used in the coating operation or operations controlled by the solvent recovery system, kg (lb), calculated using Equation 3B of this subsection
CCSR is the total mass of organic HAP in the cleaning materials used in the coating operation or operations controlled by the solvent recovery system, kg (lb), calculated using Equation 3C of this subsection
RV is the volatile organic matter collection and recovery efficiency of the solvent recovery system, percent, from Equation 2 of this subsection
(Equation 3A)
where:
ACSR is the total mass of organic HAP in the coatings used in the coating operation or operations controlled by the solvent recovery system during the month, kg (lb)
Volc,i is the total volume of coating, i, used during the month in the coating operation or operations controlled by the solvent recovery system, liters (gallons)
Dc,i is the density of coating, i, kg per liter (lb per gallon)
Wc,i is the mass fraction of organic HAP in coating, i, kg (lb) of organic HAP per kg (lb) of coating. For reactive adhesives, use the mass fraction of organic HAP emitted as determined using the method in 40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in s. NR 484.04 (24r).
m is the number of different coatings used
(Equation 3B)
where:
BCSR is the total mass of organic HAP in the thinners and other additives used in the coating operation or operations controlled by the solvent recovery system during the month, kg (lb)
Volt,j is the total volume of thinner or other additive, j, used during the month in the coating operation or operations controlled by the solvent recovery system, liters (gallons)
Dt,j is the density of thinner or other additive, j, kg per liter (lb per gallon)
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.