A-382.30 (11) (f) CONNECTION TO PRESSURIZED PUBLIC SEWER.
A-382.31 (4)-1. WHERE A VENT STACK AND STACK VENT ARE REQUIRED.
Drain stack
Branch drain
First branch interval (BI)
Second BI
Third BI
Fourth BI
Fifth BI
Stack vent
A-382.31 (4)-2. INSTALLATION OF VENT STACK AND STACK VENT.
A-382.31 (5) (a) VENTING OFFSETS OF 30 TO 45 DEGREES.
30–45
5 or more branch intervals above offset
2 feet
2 feet
Vent offset when branch
connection is made within this
portion, except when drain stack is sized as building drain
A-382.31 (5) (b) VENTS FOR OFFSETS OF MORE THAN 45 DEGREES.
Optional connection point
Five or more branch intervals above offset.
No venting required where:
the drain stack is one pipe size larger than building drain and not less in area than stack plus vent, OR
where there are no connections below two feet above the uppermost fitting of the offset
No horizontal branch connections
2 feet above to 2 feet below offset
A-382.31 (7) RELIEF VENTS FOR BUILDING DRAINS.
A-382.31 (9) FIXTURE VENTS.
A-382.31 (10)-1. CIRCUIT VENTING.
A-382.31 (10)-2. CIRCUIT VENTING.
Relief vent
Circuit vent
Branch vent
Circuit vent
WC
FD
WC
WC
CO
FD
WC
WC
LAVS
CO
No more than four fixtures per side
A-382.31 (10)-3. CIRCUIT VENTING.
Relief vent
Branch vent
Circuit vent
Circuit vent
CO
A-382.31 (10)-4. CIRCUIT VENTING.
A-382.31 (11) (a) COMMON VENTS, VERTICAL, SERVING ANY TWO FIXTURES.
BACK-TO-BACK
SIDE-BY-SIDE
A-382.31 (11) (b) COMMON VENTS, HORIZONTAL DRAINS.
A-382.31 (12) RETURN VENTS.
A-382.31 (13) (a) VERTICAL WET VENTS.
1¼ inch
fixture drain
2 inch fixture drain
1¼ inch
fixture drain
1¼ inch fixture drain
Floor
Floor
2 inches
2 inches
A-382.31 (13)-1. HORIZONTAL WET VENTS.
LAV
BT
WC
LAV
BT
Fixtures above
WC
LAV
BT
Fixtures above
3 inch
3 inch
2 inch
2 inch
1½ inch
1½ inch
1½ inch
1½ inch
WC
WC
BT
BT
LAV
LAV
LAV
A-382.31 (13)-2. WET VENTING – FLOOR OUTLET FIXTURES.
Individual vent serving as a wet vent
Common vents serving as a wet vent
Lav
Lavs
Lavs
FD
FD
FD
2 inch
2 inch
2 inch
FD
Lavs
WC
WC
WC
WC
Clean out
Relief vent serving as wet vent
Individual vent serving as a wet vent
Common vents serving as a wet vent
Lavs
Lavs
Lav
WC
WC
WC
2 inch
3 inch
2 inch
3 inch
2 inch
3 inch
Lav/DF
Circuit vent serving as a wet vent
A-382.31 (14) (a) and (b) SIZING VENT STACKS AND STACK VENTS
A-382.31 (14) (c) SIZING BRANCH VENTS SERVING A WET VENT.
A-382.31 (14) (d) SIZING INDIVIDUAL VENTS.
A-382.31 (15) (a) VENT GRADES AND CONNECTIONS.
A-382.31 (15) (b) VENT GRADES AND CONNECTIONS.
A-382.31 (16) VENT TERMINALS.
6 inches minimum
8 inches minimum
The dimension is taken from the center of the pipe as illustrated at this point
VENTS TERMINATING THROUGH ROOFS.
VENTS TERMINATING THROUGH WALLS
A-382.31 (17) (a) COMBINATION DRAIN AND VENT STACKS.
A-382.31 (17) (b) COMBINATION DRAIN AND VENT BUILDING DRAIN.
A-382.31 (17) (c) COMBINATION DRAIN AND VENT LABORATORY SINK VENTING.
A-382.32 (4) (b) INSTALLATION OF TRAPS.
36 inches maximum
Water level
Water closet with integral trap
MOST FIXTURES
15 inches maximum
36 inches maximum
STANDPIPE
FLOOR DRAIN
VERTICAL DISTANCE BETWEEN FIXTURE DRAIN OUTLET AND TRAP
HORIZONTAL DISTANCE BETWEEN FIXTURE DRAIN OUTLET AND TRAP
15 inches maximum
Pedestal fixtures
(Lavatory, shampoo sink,
drinking fountain or cuspidor)
60 inches maximum
15 inches maximum
36 inches maximum
A-382.33 (6)-1. INDIRECT WASTE PIPING.
Maximum 30 feet
Maximum 15 feet
Receptor
A-382.33 (6)-2. LOCAL WASTE PIPING.
Receptor
Maximum 30 feet
Maximum 15 feet
MAXIMUM LENGTH OF LOCAL WASTE PIPE
Indirect waste piping
A-382.33 (7) AIR-GAPS AND AIR-BREAKS.
A-382.33 (8) (a) WASTE SINKS AND STANDPIPES.
A-382.33 (8) (b) FLOOR SINKS.
A-382.33 (8) (b) FLOOR SINK WITH GRATE OPENING.
A-382.33 (8) (c)–1. LOCAL WASTE PIPING.
A-382.33 (8) (c)-2. LOCAL WASTE PIPING
A-382.33 (8) (d)-1. LOCAL WASTE PIPING SERVING WATER HEATER TEMPERATURE AND PRESSURE RELIEF VALVES.
A-382.33 (8) (d)-2. LOCAL WASTE PIPING SERVING WATER HEATER TEMPERATURE AND PRESSURE RELIEF VALVES