Register April 2021 No. 784
Chapter SPS 318
ELEVATORS, ESCALATORS, AND LIFT DEVICES
Subchapter I — Scope and Application
SPS 318.1003 Application.
Subchapter II — Definitions and Standards
SPS 318.1004 Definitions.
SPS 318.1005 Adoption of standards by reference.
Subchapter III — Administration and Enforcement
SPS 318.1007 Plan review and approval.
SPS 318.1008 Plan review actions.
SPS 318.1009 Identification of conveyances.
SPS 318.1010 Product approvals.
SPS 318.1011 Inspections and permits to operate.
SPS 318.1012 Agent municipalities.
SPS 318.1013 Accident reporting.
SPS 318.1014 Petition for variance.
SPS 318.1015 Enforcement.
SPS 318.1018 Investigations initiated by public.
Subchapter IV — Changes, Additions, or Omissions
to ASME A17.1
SPS 318.1700 Changes, additions, or omissions to ASME A17.1.
SPS 318.1701 Scope, application, and definitions.
SPS 318.1702 Electric elevators.
SPS 318.1703 Hydraulic Elevators.
SPS 318.1705 Special application elevators.
SPS 318.1707 Dumbwaiter and Type B material lifts.
SPS 318.17086 Maintenance, repair, replacement, and testing.
SPS 318.17087 Alterations.
SPS 318.17089 Code data plate.
SPS 318.170810 Acceptance inspections and tests, general requirements.
SPS 318.170811 General requirements for periodic inspections and witnessing of tests.
SPS 318.1709 Reference codes, standards, and specifications.
Subchapter V — Changes, Additions, or Omissions
to ASME A18.1
SPS 318.1800 Platform lifts and stairway lifts.
SPS 318.1801 Scope, application, and definitions.
SPS 318.1802 Vertical platform lifts.
SPS 318.1803 Inclined platform lifts.
SPS 318.1804 Inclined stairway chair lifts.
SPS 318.1808 Hydraulic driving means.
SPS 318.1809 Rope sockets.
SPS 318.1810 Routine, periodic, and acceptance inspections and tests.
SPS 318.1811 Maintenance logs.
Subchapter VI — Changes, Additions, or Omissions
to ANSI E1.42
SPS 318.4200 Entertainment technology.
SPS 318.4201 Scope and application.
SPS 318.4202 Reference codes, standards, and specifications.
SPS 318.4203 Definitions.
SPS 318.4204 Design requirements.
SPS 318.4205 Control systems.
SPS 318.4206 Safety systems.
SPS 318.4207 Installation and inspections.
SPS 318.4208 Operation, maintenance, and repair.
Ch. SPS 318 Note
Note: Chapter Ind 4 as it existed on August 31, 1988 was repealed and a new chapter ILHR 18 was created effective September 1, 1988. Chapter ILHR 18 was renumbered to be chapter Comm 18 under s. 13.93 (2m) (b) 1., Stats., and corrections made under s. 13.93 (2m) (b) 6. and 7., Stats.,
Register, October, 1996, No. 490. Corrections were made under s. 13.93 (2m) (b) 6., Stats.,
Register, April, 1998, No. 508. Chapter Comm 18 as it existed on November 30, 1999 was repealed and a new chapter Comm 18 was created effective December 1, 1999. Chapter Comm 18 as it existed on March 31, 2004, was repealed and a new chapter Comm 18 was created,
Register March 2004 No. 579, effective April 1, 2004. Subchapters II to IV of chapter Comm 18 as they exist on December 31, 2008, are repealed and new subchapters II to IV are created
Register June 2008 No. 630, effective January 1, 2009.
Chapter Comm 18 was renumbered chapter SPS 318 under s. 13.92 (4) (b) 1., Stats., Register December 2011 No. 672; Chapter SPS 318 as it existed on August 31, 2014 was repealed and a new chapter SPS 318 was created Register August 2014 No. 704, effective September 1, 2014. SPS 318.1001
SPS 318.1001 Purpose. Pursuant to ss.
101.982 and
101.983, Stats., the purpose of this chapter is to establish minimum safety standards for the design, construction, installation, operation, inspection, testing, maintenance, alteration, repair, and replacement of conveyances.
SPS 318.1002 History
History: CR 14-020: cr.
Register August 2014 No. 704, eff. 9-1-14.
SPS 318.1003(1)(a)(a) The design, construction, and installation rules of this chapter, including the acceptance-inspection requirements and the applied criteria from the standards adopted in s.
SPS 318.1005, do not apply retroactively to conveyances existing prior to the effective date of the rule unless specifically stated in the administrative rule or standard.
SPS 318.1003(1)(b)1.1. The operation, testing, maintenance, and periodic inspection requirements of this chapter apply to all conveyances that exist on or after June 1, 2020, except as provided in subd.
2. and pars.
(c) to
(e).
SPS 318.1003(1)(b)2.
2. The provisions of subd.
1. do not apply to a conveyance with a contract date of prior to January 1, 2009, that serves a dwelling unit.
SPS 318.1003 Note
Note: Although the provisions of subdivision 1. do not apply as stated above, these conveyances are subject to the requirements in section
101.983 (3) of the Statutes, which reads as follows: “If the owner and a prospective buyer of an individual residential dwelling unit that is served by a dumbwaiter or an elevator enter into a contract of sale for the unit that includes a provision requiring that the dumbwaiter or elevator be inspected, the inspection shall be performed by an elevator inspector licensed under s.
101.985 (3)."
SPS 318.1003(1)(c)1.1. The design, construction, and installation requirements of this chapter, including the acceptance-inspection requirements apply to any alterations, repairs, and replacement parts or components for any conveyance that have a contract date of on or after June 1, 2020, except as provided in subd.
2., par.
(e), and sub.
(1m).
SPS 318.1003 Note
Note: See section
SPS 318.1007 (3) for further information about plan review for alterations and replacements.
SPS 318.1003(1)(c)2.
2. The provisions of subd.
1. do not apply to a conveyance with a contract date of prior to January 1, 2009, that serves a dwelling unit.
SPS 318.1003 Note
Note: A proposed alteration for an existing conveyance may necessitate modifying other components of the conveyance to make the proposed alteration comply with this chapter — and some alterations may necessitate modifying other features of a building that must comply with requirements in chapters SPS 320 to 325, the Wisconsin Uniform Dwelling (One- and Two-Family Dwelling) Code, and chapters SPS 361 to 366, the Wisconsin Commercial Building Code.
SPS 318.1003(1)(e)
(e) Periodic inspections are not required under this chapter for any conveyances that receive periodic inspections by United States government inspectors.
SPS 318.1003(1m)
(1m) Exclusions. This chapter does not apply to any conveyances for any of the following buildings or structures:
SPS 318.1003(1m)(a)1.1. Buildings or structures located on Indian reservation land that are held either in trust by the United States, or in fee by the tribe or a tribal member.
SPS 318.1003(1m)(a)2.
2. Buildings or structures which are located on off-reservation Indian land that is held in trust by the United States – and which are held either in trust by the United States, or in fee by the tribe or a tribal member.
SPS 318.1003(1m)(b)
(b) Buildings and portions of buildings that are federally owned or exempted by federal statutes, regulations, or treaties.
SPS 318.1003(1m)(c)
(c) Portions of buildings leased to the federal government provided all of the following conditions are met: