SPS 318.4203(1)(a) (a) “Authority having jurisdiction” means the department of safety and professional services, except as designated under s. SPS 318.1012.
SPS 318.4203(1)(b) (b) “Lifting load” means the load that the equipment is designed and installed to lift at the rated speed.
SPS 318.4203(1)(c) (c) “Qualified person” means one who is licensed for the corresponding work by the department under s. SPS 305.991.
SPS 318.4203(1)(d) (d) “Static load” means the live load that the orchestra pit lift is designed and installed to support while the lift platform is not in motion as provided by the manufacturer upon installation or as approved by the department.
SPS 318.4203(2) (2)   This is a department definition in addition to the definitions in ANSI E1.42 chapter 3: “Orchestra pit lift” has the meaning given in s. SPS 318.1004 (10) (g).
SPS 318.4203 History History: CR 19-118: cr. Register May 2020 No. 773, eff. 6-1-20.
SPS 318.4204 SPS 318.4204Design requirements.
SPS 318.4204(1)(1)   Substitute the following wording for the requirements in ANSI E1.42 section 4.3.3: The horizontal gaps between the edges of the lift platform floor and fixed floors shall be greater than zero, in order to avoid direct contact, and not greater than 3/4 inch.
SPS 318.4204(2) (2)   This is a department rule in addition to the requirements in ANSI E1.42 section 4.1.4.1: The means of stopping and preventing unintended movement of the lift platform shall be tested at 100% of rated load.
SPS 318.4204(3) (3)   Substitute the following wording for the requirements in ANSI E1.42 section 4.1.4.1.2: An inherently self-locking gear reducer or actuator that resists motion by a restraining force 150% or greater than the applied force may be permitted for use as secondary means against uncontrolled or unintended movement, where available from the manufacturer. Where the secondary means is installed, it shall be inspected by a qualified person.
SPS 318.4204(4) (4)   This is a department rule in addition to requirements in ANSI E1.42 section 4.3.3.1: The horizontal gaps shall be measured between the edge of the lift platform surface and the edge of the fixed floor.
SPS 318.4204(5) (5)   This is a department rule in addition to requirements in ANSI E1.42 section 4.6.1: The illumination levels shall be a minimum of 19 foot candles at the controller with the door open or closed, at the main disconnect location, and at the drive machines. The remainder of the pit floor shall be a minimum of 10 foot candles, including at access levels, the route to controller and disconnect location, and any other Group 2 areas, in accordance with ASME A17.1, section 2.2.5, as applicable.
SPS 318.4204 History History: CR 19-118: cr. Register May 2020 No. 773, eff. 6-1-20.
SPS 318.4205 SPS 318.4205Control systems.
SPS 318.4205(1)(1)   This is a department informational note to be used under ANSI E1.42 section 5.1.3:
SPS 318.4205 Note Note: See s. SPS 316.620 and NEC 620 for additional requirements.
SPS 318.4205(2) (2)   Substitute the following wording for the requirements in ANSI E1.42 section 5.5.4: When actual and stored position data differ, setting or restoring position data for the lift shall only be done by qualified or competent persons.
SPS 318.4205(3) (3)   Substitute the following wording for the requirements in ANSI E1.42 section 5.6.1.2: The circumstances requiring the override shall be investigated by a competent person before an override is engaged and may only be performed by an authorized person in communication with the operator. Override devices shall be located in a position so as to provide the authorized person a clear line of sight to the condition requiring the override. Indicators at all operator positions shall change state to inform the operator that the override has been engaged. The override device may not initiate motion without the direct action of the lift operator and shall limit speed and direction of travel while engaged.
SPS 318.4205 History History: CR: 19-118: cr. Register May 2020 No. 773, eff. 6-1-20.
SPS 318.4206 SPS 318.4206Safety systems.
SPS 318.4206(1)(1)   This is a department rule in addition to requirements in ANSI E1.42 section 6.3.1.2: Suitable active guarding mechanisms shall be per manufacturer's recommendations or as approved by the department.
SPS 318.4206(2) (2)   This is a department rule in addition to requirements in ANSI E1.42 section 6.4.6: The emergency unlocking or unlatching release systems shall be accessible only to competent persons.
SPS 318.4206 History History: CR: 19-118: cr. Register May 2020 No. 773, eff. 6-1-20.
SPS 318.4207 SPS 318.4207Installation and inspections.
SPS 318.4207(1)(1)   Substitute the following for the requirements in ANSI E1.42 section 7.1.1: Orchestra pit lifts shall be tested in accordance with the applicable criteria in ASME A17.1 section 8.6.
SPS 318.4207(2) (2)   The requirement in ANSI E1.42 section 7.1.4 is not included as part of this subchapter.
SPS 318.4207(3) (3)   Substitute the following for the requirements in ANSI E1.42 section 7.2.2: Compliance testing may be observed by the department.
SPS 318.4207(4) (4)   Substitute the following wording for the requirements in ANSI E1.42 section 7.9.7.5: Any additional issues as identified by the manufacturer's instructions or noted by the department during previous inspections.
SPS 318.4207(5) (5)   These are department rules in addition to requirements in ANSI E1.42 chapter 7:
SPS 318.4207(5)(a) (a) Periodic inspections shall be made at intervals not longer than one year.
SPS 318.4207(5)(b) (b) Periodic tests in conformance with ANSI E1.42 sections 7.3, 7.4, 7.5, and 7.8 shall be made at intervals not longer than one year.
SPS 318.4207(5)(c) (c) Periodic tests in conformance with ANSI E1.42 sections 7.6, 7.7, 7.9, and 7.10 shall be made at intervals not longer than 5 years.
SPS 318.4207 History History: CR: 19-118: cr. Register May 2020 No. 773, eff. 6-1-20.
SPS 318.4208 SPS 318.4208Operation, maintenance, and repair.
SPS 318.4208(1)(1)   Substitute the following wording for the requirements in ANSI E1.42 section 8.1.2: A written record of all trainings for competent persons and authorized persons, including the names of the competent persons, the names of the authorized persons, the names and affiliations of the trainers, and the dates of any training received from the trainers shall be maintained and shall be made available for inspection on request.
SPS 318.4208(2) (2)   Substitute the following wording for the requirements in ANSI E1.42 section 8.2.4: If a fault, malfunction, damage, unusual sound, or other unusual performance of the orchestra pit lift occurs, then the operator shall stop the lift and evaluate the lift status. If corrective action cannot be taken within the authority of the operator, then the lift shall be taken out of service and referred to a competent person. Any such event and resulting actions shall be reported in accordance with section 8.3.4.
SPS 318.4208(3) (3)   Substitute the following wording for the requirements in ANSI E1.42 section 8.3.3: For new installations, the initial maintenance control program shall be provided by the equipment manufacturer. For existing equipment undergoing any alteration, repair, or replacement, the maintenance control program for the altered, repaired, or replaced components shall be provided by the person or firm performing the work. The maintenance control program shall be made available at the scheduled time for service, tests, or inspection.
SPS 318.4208(4) (4)   This is a department rule in addition to requirements in ANSI E1.42 section 8.3.4: A paper copy of the record shall be available.
SPS 318.4208(5) (5)   Substitute the following wording for the requirements in ANSI E1.42 section 8.4.1.2: Alterations and repairs to orchestra pit lifts manufactured to this standard shall be performed or supervised by qualified persons, in accordance with s. 101.984, Stats.
SPS 318.4208(6) (6)   Substitute the following wording for the requirements in ANSI E1.42 section 8.4.6.1: Orchestra pit lifts subject to this subchapter shall be inspected and operationally tested in accordance with ANSI E1.42 by a qualified person after any alterations, replacements, or repairs listed in table SPS 318.1007-1, as applicable. An orchestra pit lift may not be returned to service until it is in compliance with ANSI E1.42 section 8.4.6.
SPS 318.4208 History History: CR: 19-118: cr. Register May 2020 No. 773, eff. 6-1-20.